Olympus' USPM-RU-W NIR Micro-Spectrophotometer performs fast, accurate spectrometry across a wide range of wavelengths of visible light to near-infrared.The ability to easily measure reflectivity of extremely small areas or curved surfaces that cannot be measured using ordinary spectrophotometers, makes the USPM-RU-W optimally suited for analyzing optical elements or minute electronics parts.
■ Reflectivity, Film thickness, Object color, and transmittance measured in seconds
■ Wide range of wavelength from 380 to 1050 nm
■ Measures reflectivity on curved surface without contact
Measure the reflectivity of a minute area with a diameter ranging from 17 to 70 um
Use reflectivity data to measure the thickness of single-layer or multi-layer films of approximately 50 nm to 10 μm.
Display an XY chromaticity diagram, an L*a*b* chromaticity diagram, and their related numeric values based on reflectivity data.
Measure the transmittance of a plane sample by transmitting 2 mm parallel beams of lights through the sample to the spectrophotometry acceptance elements.
Measure the reflectivity at an incidence angle of 45 degrees by reflecting 2 mm parallel beams of lights to the spectrophotometry acceptance elements.
Quick, high repeatability measurements can be achieved in seconds using a flat field grating, line sensor and high-speed spectrophotometry.
Olympus has designed a new dedicated objective lens that provides non-contact measurements across an area of 17 to 70 μm diameters. The new lens provides high repeatability on even curved surfaces or minute electronic parts.
Accurate measurement of surface reflectivity can be performed without the costly steps needed to prevent rear surface reflection. Rear surface-reflected light is reduced by means of special optics that block all out-of-focus light reflection similar to a confocal system. Whether your optical component is spherical,aspherical or flat, the USPM-RU-W does not require sample preparation through anti-reflection treatments.
The single-layer or multi-layer film thickness can be analyzed according to the measured spectral reflectivity data. You can select the optimum measurement method for the application.
This method is used to calculate film thickness based on the periods between the peaks and valleys of the measured spectral reflectivity value, and is effective for measuring single-layer film. No complicated settings are required, so measuring film thickness is easy.
This method is used to calculate film thickness based on the periods between measured spectral reflectivity values, and is effective for measuring single-layer and multilayer films. The Fourier transform method eliminates noise, thus making analysis possible when it is difficult to detect peak and valley values.
This method is used to calculate film thickness by estimating which structure has the smallest difference between the measured spectral reflectivity and the calculated reflectivity for that structure, and is effective for measuring single-layer and multilayer films. The curve fit method also makes it possible to analyze thin film in which peak and valley values are not apparent.
Satisfies Diverse Measurement Needs at High Speed and With High Precision
Mobile Phone Camera Lenses
Projector Lenses
Digital Camera Lenses
Spectacle Lenses
LED Packages
Printed Circuit Boards
LCD color filters
Optical films
Prisms
Mirrors
Reflectivity measurement | Transmittance Measurement*1 | Reflectivity Measurement for 45-Degrees*1 | |||
Name | NIR Micro-Spectrophotometer |
Transmittance measurement set for
NIR Micro-Spectrophotometer |
45-degree reflectance measurement set for
NIR Micro-Spectrophotometer | ||
Model | USPM-RU-W | ||||
Measured wavelength | 380 to 1050 nm | ||||
Measurement method | Compared with a reference sample for measurement | Transmissivity is measured with 100% as standard | Compared with a reference sample for measurement | ||
Measurement range | See the specifications of the objective lens below | Approx. 2.0 mm in diameter | |||
Measurement repeatability(3σ) *2 | Reflectivity measurement | During use of 10x and 20x objective lenses |
±0.02% or less (430 to 1010 nm)
±0.2% or less (Except as described above) |
±0.3% or less (430 to 1010 nm)
±1.0% or less (Except as described above) | |
During use of a 40x objective lens |
±0.05% or less (430 to 950 nm)
±0.5% or less (Except as described above) | ||||
Film thickness measurement | ±1% | - | |||
Wavelength display resolution | 1nm | ||||
Lighting accessory | Dedicated halogen light source, JC12V 55W (Average life: 700 hours) | ||||
Shift stage |
Loading surface size: 200 (W) x 200 (D) mm
With stand load: 3 kg Operating range: (XY) ±40 mm, (Z) 125 mm | ||||
Tilt stage | - |
Loading surface size: 140 (W) x 140 (D) mm
Withstand load: 1 kg Operating range: (XT) ±1*, (YT) ±1* | |||
Weight | Main body: Approx. 26 kg (not including PC) | Main body: Approx. 31 kg (not including PC)*3 | |||
Control power box: Approx. 6.7 kg | |||||
Dimensions | Main body: 360 (W) x 446 (D) x 606 (H) mm | Main body: 360 (W) x 631 (D) x 606 (H) mm | |||
Control power box: 250 (W) x 270 (D) x 125 (H) mm (Protruding parts are not included) | |||||
Power specifications | Input specifications: AC 100-240V (110V) 50/60Hz | ||||
Operating environment |
Horizontal place not subject to vibration
Temperature: 15 ºC to 30 ºC Humidity: 15% to 60% RH (Free from dew condensation) | ||||
*1 Optional unit *2 Measured under the measurement conditions of our company. *3 The total weight of both the transmissivity measurement set and 45-degrees reflectivity measurement set installed is approx. 33 kg.
Model | USPM-OBL10X | USPM-OBL20X | USPM-OBL40X |
Magnification | 10x | 20x | 40x |
Measurement NA*4 | 0.12 | 0.24 | 0.24 |
Measurement range*5 | 70μm | 35μm | 17.5μm |
Operating distance | 14.3mm | 4.2mm | 2.2mm |
Operating distance | ±5 mm or more | ±1 mm or more | ±1 mm or more |
*4 It differs from objective lens' NA.
*5 Spot diameter
Change the layout and position, size, and visibility of each window according to the measurement purpose and user needs.
Spectral reflectivity/transmissivity graphs and text, color measurement (XY and L*a*b* chromaticity diagrams), and film thickness measurement values can be displayed on one screen for easy understanding.
Positioning the measuring point is easy by using a focusing window for Z axis alignment and centering (CT) window for X and Y axis alignment.
The USPM-RU-W software can be configured to achieve optimum performance for your specific sample.
System can be configured to provide good / no good designations automatically.
Copyright OLYMPUS CORPORATION, Alle Rechte vorbehalten.
Global | Nutzungsbedingungen | Datenschutzerklärung | Cookies | Über uns | Careers | Careers | Sitemap
Copyright OLYMPUS CORPORATION, Alle Rechte vorbehalten.
Global | Nutzungsbedingungen | Datenschutzerklärung | Cookies | Über uns | Imprint | Careers | Careers | Sitemap
Diese Seite verwendet Cookies, um die Leistung zu verbessern, Datenverkehr zu analysieren und Werbeanzeigen zu personalisieren. Wenn Sie Ihre Browser-Einstellungen nicht ändern, werden weiterhin Cookies auf dieser Webseite verwendet. Um zu erfahren wie Cookies auf dieser Webseite verwendet werden und wie Sie unsere Verwendung von Cookies beschränken, lesen Sie unsere Cookie-Richtlinie.