Olympus Logo

Contatti Contatti

  • Prodotti▾
    • Soluzioni NDT▾
      • Rilevatore di difetti▾
        • Rilevatori di difetti ad ultrasuoni portatili
        • Strumenti ad ultrasuoni phased array
        • Prodotti eddy current
        • Eddy Current Array Products
        • Controllo di materiali compositi
      • Misuratori di spessore portatili▾
        • 27MG
        • 45MG
        • 38DL PLUS
        • Magna-Mike 8600
        • 35RDC
        • Trasduttori ed accessori
      • Sonde e trasduttori▾
        • Trasduttore a singolo elemento e doppio elemento
        • Eddy Current Probes
        • Probes for Tube Inspection
        • Sonde phased array
        • BondMaster Probes
      • Sistemi di ispezione automatizzati▾
        • Wheel Inspection System
        • Soluzioni per l’ispezione di barre
        • Soluzioni per l’ispezione di tubi
        • Friction Stir Weld Inspection System
      • NDT Systems Instrumentation ▾
        • FOCUS PX / PC / SDK
        • QuickScan
      • Scanner industriali▾
        • Weld Inspection Scanners
        • Corrosion Inspection Scanners
        • Scanner per ispezione di componenti aerospaziali e pale eoliche
        • Scanner Accessories
      • Olympus Scientific Cloud
    • Analizzatori XRF e XRD▾
      • Analizzatori XRF portatili▾
        • Vanta
        • Vanta Element
        • DELTA Professional
      • Analizzatori XRF compatti e portatili▾
        • Vanta
        • Vanta Element
        • GoldXpert
        • Xpert for Consumer/RoHS
      • Analizzatori XRF per linee di produzione▾
        • FOX-IQ
      • Analizzatori XRD▾
        • Sistema XRD portatile TERRA
        • Sistema XRD da banco BTX
      • Soluzioni OEM▾
        • X-STREAM
      • Soluzioni per applicazioni principali
      • Olympus Scientific Cloud
    • Soluzioni per Microscopia▾
      • Scanning Probe Microscopy▾
        • OLS4500
      • Microscopi confocali laser▾
        • OLS5100
      • Microscopi digitali
      • Microscopi di misura▾
        • STM7
        • STM7-BSW
      • Microscopio per pulizia tecnica▾
        • OLYMPUS CIX100
      • Microscopi ottici▾
        • Microscopi verticali
        • Microscopi invertiti
        • Modular Microscopes
      • Microscopi per l'ispezione dei display a semiconduttori e schermo piatto▾
        • MX63 / MX63L
        • AL120
        • AL120-12
      • Microscopi stereoscopici▾
        • SZX16
        • SZX10
        • SZX7
        • SZ61/SZ51
      • Fotocamere digitali▾
        • DP74
        • SC180
        • UC90
        • DP27
        • SC50
        • LC30
        • DP22
        • XM10
        • XM10IR
      • Software di analisi delle immagini▾
        • OLYMPUS Stream
      • Micro Spectrophotometer▾
        • USPM-RU-W
        • USPM-RU III
      • Obiettivi▾
        • MPLAPON
        • MPLAPON-Oil
        • MPLN
        • MPLN-BD
        • MPLFLN
        • MPLFLN-BD
        • MPLFLN-BDP
        • LMPLFLN
        • LMPLFLN-BD
        • SLMPLN
        • LCPLFLN-LCD
        • LMPLN-IR/LCPLN-IR
        • White Light Interferometry Objective
        • Micrometer
      • Componenti di microscopi OEM per l'integrazione▾
        • Equipment Integration Solutions
        • Objective Lenses
        • Optical Microscope Frames
        • Super Wide Tube Lens
        • Optical Microscope Modules
        • Modular Microscope Assemblies
      • Microscope FAQ
    • Videoscopi, Boroscopi▾
      • Videoscopi industriali▾
        • IPLEX NX
        • IPLEX GAir
        • IPLEX GX/GT
        • IPLEX G Lite
        • IPLEX TX
        • Soluzione IPLEX con lungo endoscopio
      • Fibroscopi industriali▾
        • Fibroscopi di piccolo diametro
      • Boroscopi rigidi industriali▾
        • Boroscopi rigidi standard
        • Boroscopi a prisma mobile
        • Boroscopi a prisma mobile con zoom
        • MK Mini-scope modulare
        • Boroscopi per motori aeronautici
      • Fonte di luce
      • Software InHelp▾
        • InHelp
  • Settori industriali
  • Blog
  • Risorse
  • Assistenza clienti▾
    • Contatti
    • Olympus Scientific Cloud
    • Accademia di Formazione
    • Customer Service
    • Centri di Assistenza
    • Scarica Software
    • Product Information
    • Prodotti fuori produzione e obsoleti
    • Product Service Termination List
    • Certificazioni ISO
    • MSDS Datasheets
    • Terms and Conditions of Supply
    • CIC
    • Olympus Technolab
    • Microscope Classroom
    • Compliance and Ethics at Olympus
    • Same Day Shipping Program
    • Custom Financing Solutions
  • Rentals
  • Shop
  • Ricerca
  • My Account
    • IMS Log in
    • IMS Registration
    • My Apps
    • My Devices
    • My Data
    • OSC Marketplace
    • My Organization
    • OSC Log in
    • OSC Log in
    • Log Out
    • Log Out
Soluzioni industriali
Soluzioni per Microscopia

USPM-RU III

ContattiContatti
Richiedi un preventivoRichiedi un preventivo
Richiedi una DemoTesta un’applicazioneRichiedi una DemoTesta un’applicazione
USPM-RUIII Micro Spectrophotome
Home/ Prodotti/ Micro Spectrophotometer/ USPM-RU III
Loading...
  • Panoramica
  • Specifiche tecniche
  • Risorse

Panoramica

The USPM-RU III is a reflectometer that provides highly accurate spectral reflectivity measurements of small, curved, and thin samples without interference from rear surface-reflected light.
*This product is not available in all locations.

Measuring Image
Measuring Image

Measuring even minute areas

The curved surface of the lens can be measured from a minute spot as small as ø60 µm formed on the sample surface. This provides the ability to use a goniometer to examine even the curved side lenses or other optical component.


Principle of Eliminating Rear Surface Reflection
Principle of Eliminating Rear Surface Reflection

Reduces backside interference

Accurate measurement of surface reflectivity can be performed without the costly steps that are typically needed to prevent rear surface reflection. Rear surface-reflected light is reduced by means of special optics that block out all out of focus light reflection similar to a confocal system. Whether your optical component is spherical, aspherical or flat the USPM-RU III does not require sample prep through anti-reflection treatments


Fast Results

Quick, highly repeatable measurements can be achieved in seconds using a flat filed grating, line sensor and high -speed spectrophotometry.


XY Chromaticity
XY Chromaticity

X-Y Chromaticy Diagrams and L*A*B Measurement

Object color can be measured based on spectrophotometric colorimetry determined from the prismatic reflectivity.


Software

Reflectivity graph image
Reflectivity graph image
Reflectivity text data image
Reflectivity text data image

Specifiche tecniche

Lens Spectral Reflectivity Measurement Device USPM-RU III: Specifications

Measurement wavelength 380nm - 780nm
Measurement method Comparison measurement using reference specimen
Sample N.A.* 0.12 (using 10x objective lens)
0.24 (using 20x objective lens)
* it differs from objective lens' N.A.
Sample W.D. 10.1 mm (using 10x objective lens)
3.1 mm (using 20x objective lens)
Sample curvature radius -1R - ∞, +1R - ∞
Sample measurement range Approximately ø60 µm (using 10x objective lens)
Approximately ø30 µm (using 20x objective lens)
Measurement repeatability (2σ) ±0.1 % and less (during 380 nm - 410 nm measurement)
±0.01 % and less (during 410 nm - 700 nm measurement)
Display resolution 1 nm
Measurement time A few secs-several secs (it differs from sampling time)
Light source Halogen lamp 12 V 100W
Z-direction movement range of the stage 85mm
PC interface USB
Weight Unit Approximately 20 kg
Power source for light source: Approximately 3 kg
Control box: Approximately 8 kg
External dimensions Unit: 300 (W) x 550 (D) x 570 (H) mm
Power source for light source: 150 (w) x 250 (D) x 140 (H) mm
Control box: 220 (W) x 250 (D) x 140 (H) mm
Power Source Power source for light source: 100 V (2.8A)/220 V AC
Control box: 100 V (0.2A)/220V AC
Environment for use Installed at the horizontal plane with no vibration
Temperature: 23 ±5°C
Humidity: 60% or less
An environment is not subject to air fluctuation

* Absolute accuracy complying with traceability system is not guaranteed.

Risorse

Cataloghi

USPM-RUIII Micro Spectrophotome
Sorry, this page is not available in your country
Let us know what you're looking for by filling out the form below.

Contatti

Please, choose division
Iscrivendosi alla e-newsletter si riceveranno informazioni su offerte speciali, sugli ultimi prodotti o le nuove applicazioni.

  • ContattiContatti
  • Richiedi un preventivoRichiedi un preventivo
  • Richiedi una DemoTesta un’applicazioneRichiedi una DemoTesta un’applicazione
  • Contatti
  • Soluzioni NDT
  • Analizzatori XRF e XRD
  • Soluzioni per Microscopia
    • Scanning Probe Microscopy
    • Microscopi confocali laser
    • Microscopi digitali
    • Microscopi di misura
    • Microscopio per pulizia tecnica
    • Microscopi ottici
    • Microscopi per l'ispezione dei display a semiconduttori e schermo piatto
    • Microscopi stereoscopici
    • Fotocamere digitali
    • Software di analisi delle immagini
    • Micro Spectrophotometer
      • USPM-RU-W
      • USPM-RU III
    • Obiettivi
    • Componenti di microscopi OEM per l'integrazione
    • Microscope FAQ
  • Videoscopi, Boroscopi
  • Iscriversi alle Newsletters
Home/ Prodotti/ Micro Spectrophotometer/ USPM-RU III
Stampa

Copyright OLYMPUS CORPORATION, All rights reserved.

Globale | Condizioni d'uso | Informativa sulla privacy | Cookies | Chi siamo | Careers | Careers | Mappa del sito

Copyright OLYMPUS CORPORATION, All rights reserved.

Globale | Condizioni d'uso | Informativa sulla privacy | Cookies | Chi siamo | Imprint | Careers | Careers | Mappa del sito

  • Youtube
  • LinkedIn
  • Twitter
  • Facebook

Questo sito utilizza cookie per migliorare le performance, analizzare il traffico e misurare l’efficacia delle pubblicità. Se non modifichi le impostazioni internet, i cookie continueranno a essere usati in questo sito internet. Per maggiori informazioni sulle modalità d’uso dei cookie per questo sito internet e sulle modalità di restrizione dell’uso dei cookie, riferirsi alla nostra politica sui cookie.

OK
Cancel

Redirecting

You are being redirected to our local site.