Spot weld transducers are specifically designed to provide optimal performance for nondestructive testing of numerous types of spot welds, including those used in automotive and industrial applications.

Olympus NDT ultrasonic spot weld transducers are specifically designed to provide optimal performance for nondestructive testing of numerous types of spot welds, including those used in automotive and industrial applications. Ultrasonic inspection of spot welds involves the analysis of what is known as the "ringdown" of sound within the weld nugget. Unlike many other direct measurement techniques, spot-weld inspection looks at the characteristics of the multiple echoes returned from sound energy ringing within the weld nugget. Echo spacing, sound attenuation, and intermediate echo detection are some of the indicators of weld quality that are analyzed by trained inspectors.

Our transducers have excellent signal-to-noise ratios due to broadband design, which is critical for distinguishing good welds from poor welds. These transducers are available in a multitude of sizes in 0.5 mm increments to ensure that the proper transducers are available for a variety of weld nugget sizes. Element sizes are engraved with both English and metric units for worldwide use. The versatile design of these spot weld transducers allows them to be used with either a soft membrane captive water column or a hard tip delay line. Transducers, delay lines, and water columns are sold separately.


Top Row: Transducer, Water Column, Membranes Bottom Row: Transducer, Delay Line, Delay Line Retaining Ring

Transducer Configurator

Select either delay line or water column.
(Transducers, delay lines, delay line retaining rings, water columns, and membranes need to be ordered separately.)

Frequency (MHZ)
Nominal Element Size (in)
Transducer Type
Search Results
Item NumberPart CodeFrequency
(MHz)
Nominal Element Size (mm)Nominal Element Size (in)SeriesDelay LinesDelay Line Retaining RingsWater Columns

U8415025

Delay Line, Water Column Spot-Weld Transducer. 15 MHz, 0.118 in./3.0 mm element diameter. For use with DLCW-1003 Water Column or SWDL-30 / SWDL-32 Delay Line & SWRR-1 Retaining Ring (not included). Includes Test Form Certificate
V2330
15 3 0.118 VIDEOSCANSWDL-32SWDL-30SWRR-1DLCW-1003

U8415026

Delay line / water column Spot-Weld Transducer. 15 MHz, 0.138 in./3.5 mm element diameter. For use with DLCW-2003 water column or SWDL-35 / SWDL-37 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2335
15 3.5 0.138 VIDEOSCANSWDL-35SWDL-37SWRR-2DLCW-2003

U8415027

Delay line / water column Spot-Weld Transducer. 15 MHz, 0.157 in./4.0 mm element diameter. For use with DLCW-2003 water column or SWDL-40 / SWDL-42 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2340
15 4 0.157 VIDEOSCANSWDL-40SWDL-42SWRR-2DLCW-2003

U8415028

Delay line / water column Spot-Weld Transducer. 15 MHz, 0.177 in./4.5 mm element diameter. For use with DLCW-2003 water column or SWDL-45 / SWDL-47 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2345
15 4.5 0.177 VIDEOSCANSWDL-45SWDL-47SWRR-2DLCW-2003

U8415029

Delay Line, Water Column Spot-Weld Transducer. 15 MHz, 0.197 in./5.0 mm Element Diameter. For use with DLCW-2003 Water Column or SWDL-50 / SWDL-52 Delay Line & SWRR-2 Retaining Ring (not included). Includes Test Form Certificate
V2350
15 5 0.197 VIDEOSCANSWDL-52SWDL-50SWRR-2DLCW-2003

U8415030

Delay line / water column Spot-Weld Transducer. 15 MHz, 0.217 in./5.5 mm element diameter. For use with DLCW-2003 water column or SWDL-55 / SWDL-57 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2355
15 5.5 0.217 VIDEOSCANSWDL-55SWDL-57SWRR-2DLCW-2003

U8415031

Delay line / water column Spot-Weld Transducer. 15 MHz, 0.236 in./6.0 mm element diameter. For use with DLCW-2003 water column or SWDL-60 / SWDL-62 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2360
15 6 0.236 VIDEOSCANSWDL-60SWDL-62SWRR-2DLCW-2003

U8415032

Delay Line, Water Column Spot-Weld Transducer. 15 MHz, 0.256 in./6.5 mm Element Diameter. For use with DLCW-3003 Water Column or SWDL-65/ SWDL-67 Delay Line & SWRR-3 Retaining Ring (not included). Includes Test Form Certificate
V2365
15 6.5 0.256 VIDEOSCANSWDL-65SWDL-67SWRR-3DLCW-3003

U8415033

Delay line / water column Spot-Weld Transducer. 15 MHz, 0.315 in./8.0 mm element diameter. For use with DLCW-3003 water column or SWDL-80 / SWDL-82 delay line & SWRR-3 retaining ring (not included). Includes Test Form Certificate
V2380
15 8 0.315 VIDEOSCANSWDL-80SWDL-82SWRR-3DLCW-3003

U8415024

Delay Line, Water Column Spot-Weld Transducer. 15 MHz, 0.98 in./2.5 mm Element Diameter. For use with DLCW-1003 Water Column or SWDL-325/ SWDL-27 Delay Line & SWRR-1 Retaining Ring (not included). Includes Test Form Certificate
V2325
15 2.5 0.98 VIDEOSCANSWDL-25SWDL-27SWRR-1DLCW-1003

U8415034

Delay line / water column Spot-Weld Transducer. 20 MHz, 0.098 in./ 2.5 mm element diameter. For use with DLCW-1003 water column or SWDL-25 / SWDL-27 delay line & SWRR-1 retaining ring (not included). Includes Test Form Certificate
V2425
20 2.5 0.098 VIDEOSCANSWDL-25SWDL-27SWRR-1DLCW-1003

U8415035

Delay line / water column Spot-Weld Transducer. 20 MHz, 0.118 in./ 3.0 mm element diameter. For use with DLCW-1003 water column or SWDL-30 / SWDL-32 delay line & SWRR-1 retaining ring (not included). Includes Test Form Certificate
V2430
20 3 0.118 VIDEOSCANSWDL-30SWDL-32SWRR-1DLCW-1003

U8415036

Delay line / water column Spot-Weld Transducer. 20 MHz, 0.138 in./3.5 mm element diameter. For use with DLCW-2003 water column or SWDL-35 / SWDL-37 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2435
20 3.5 0.138 VIDEOSCANSWDL-35SWDL-37SWRR-2DLCW-2003

U8415037

Delay line / water column Spot-Weld Transducer. 20 MHz, 0.157in./4.0 mm element diameter. For use with DLCW-2003 water column or SWDL-40 / SWDL-42 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2440
20 4 0.157 VIDEOSCANSWDL-40SWDL-42SWRR-2DLCW-2003

U8415038

Delay line / water column Spot-Weld Transducer. 20 MHz, 0.177 in./4.5 mm element diameter. For use with DLCW-2003 water column or SWDL-45 / SWDL-47 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2445
20 4.5 0.177 VIDEOSCANSWDL-45SWDL-47SWRR-2DLCW-2003

U8415039

Delay line / water column Spot-Weld Transducer. 20MHz, 0.197 in./5.0 mm element diameter. For use with DLCW-2003 water column or SWDL-50 / SWDL-52 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2450
20 5 0.197 VIDEOSCANSWDL-50SWDL-52SWRR-2DLCW-2003

U8415040

Delay line / water column Spot-Weld Transducer. 20 MHz, 0.217 in./5.5 mm element diameter. For use with DLCW-2003 water column or SWDL-55 / SWDL-57 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2455
20 5.5 0.217 VIDEOSCANSWDL-55SWDL-57SWRR-2DLCW-2003

U8415041

Delay line / water column Spot-Weld Transducer. 20 MHz, 0.236 in./6.0 mm element diameter. For use with DLCW-2003 water column or SWDL-60 / SWDL-62 delay line & SWRR-2 retaining ring (not included). Includes Test Form Certificate
V2460
20 6 0.236 VIDEOSCANSWDL-60SWDL-62SWRR-2DLCW-2003

U8415042

Delay line / water column Spot-Weld Transducer. 20 MHz, 0.256 in./6.5 mm element diameter. For use with DLCW-3003 water column or SWDL-65 / SWDL-67 delay line & SWRR-3 retaining ring (not included). Includes Test Form Certificate
V2465
20 6.5 0.256 VIDEOSCANSWDL-65SWDL-67SWRR-3DLCW-3003

Captive Water Column Membranes (Includes O-Rings)

fits DLCW-1003 fits DLCW-2003 fits DLCW-3003
Part Number Desc. (qty.) Part Number Desc. (qty.) Part Number Desc. (qty.)
DLCW-1003-MK25 25 Std. DLCW-2003-MK25 25 Std. DLCW-3003-MK25 25 Std.
DLCW-1003-MK50 50 Std. DLCW-2003-MK50 50 Std. DLCW-3003-MK50 50 Std.
DLCW-1003-MKX25 25 Hvy. Duty DLCW-2003-MKX25 25 Hvy. Duty DLCW-3003-MKX25 25 Hvy. Duty
DLCW-1003-MKX50 50 Hvy. Duty DLCW-2003-MKX50 50 Hvy. Duty DLCW-3003-MKX50 50 Hvy. Duty