All standard dual element transducers feature Automatic Probe Recognition, which automatically recalls a default V-path correction for each specific transducer.
| Item Number | Part Code | Frequency (MHz) | Connector Type | Connector Location | Range in Steel (mm) | Range in Steel (in) | Temperature Range °F | Temperature Range °C | Tip Diameter (mm) | Tip Diameter (in) | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
U8450017
| D797-SM | 2 | Microdot | Straight | 3.5 - 635 | 0.150 - 25 | -5 - 752 | -20 - 400 | 22.9 | 0.900 | ||
U8450016
| D797 | 2 | Potted | Right Angle | 3.5 - 635 | 0.150 - 25 | -5 - 752 | -20 - 400 | 22.9 | 0.900 | ||
U8450021
| D799 | 5 | Potted | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 300 | -20 - 150 | 11 | 0.434 | ||
U8450011
| D791-RM | 5 | Microdot | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 752 | -20 - 400 | 11 | 0.434 | ||
U8450008
| D790-SL | 5 | LEMO | Straight | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 | ||
U8450009
| D790-SM | 5 | Microdot | Straight | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 | ||
U8450007
| D790-RL | 5 | LEMO | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 | ||
U8450002
| D790 | 5 | Potted | Straight | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 | ||
U8620225
| MTD705 | 5 | Lepra/Con | Right Angle | 1.0 - 19 | 0.040 - 0.75 | 32 - 122 | 0 - 50 | 5.1 | 0.200 | ||
U8450010
| D791 | 5 | Potted | Right Angle | 1.0 - 508 | 0.040 - 20 | -5 - 932 | -20 - 500 | 11 | 0.434 | ||
U8450014
| D794 | 5 | Potted | Straight | 0.75 - 50 | 0.030 - 2 | 32 - 122 | 0 - 50 | 7.2 | 0.283 | ||
U8450018
| D798 | 7.5 | Potted | Right Angle | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 7.2 | 0.283 | ||
U8450019
| D798-LF | 7.5 | Potted | Right Angle | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 8.9 | 0.35 | ||
U8450020
| D798-SM | 7.5 | Microdot | Straight | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 7.2 | 0.283 | ||
U8454013
| D7226 | 7.5 | Potted | Right Angle | 0.71 - 100 | 0.028 - 4 | -5 - 300 | -20 - 150 | 8.9 | 0.35 | ||
U8450012
| D792 | 10 | Potted | Straight | 0.5 - 25 | 0.020 - 1 | 32 - 122 | 0 - 50 | 7.2 | 0.283 | ||
U8450013
| D793 | 10 | Potted | Right Angle | 0.5 - 25 | 0.020 - 1 | 32 - 122 | 0 - 50 | 7.2 | 0.283 |
Contact Transducers
| Frequency | Element Diameter | Transducers | Item Number | |
| mm | inches | |||
| 0.5 | 25 | 1.00 | M101-SB* | U8400017 |
| 1.0 | 25 | 1.00 | M102-SB* | U8400018 |
| 1.0 | 13 | 0.5 | M103-SB* | U8400020 |
| 2.25 | 13 | 0.5 | M106-RM | U8400023 |
| M106-SM | U8400025 | |||
| 2.25 | 13 | 0.5 | M1036 | U8400020 |
5.0 | 13 | 0.5 | M109-RM | U8400027 |
| M109-SM | U8400028 | |||
| 5.0 | 6 | 0.25 | M110-RM | U8400030 |
|
M110-SM
M110H-RM** |
U8400031
U8400029 | |||
| 10 | 6 | 0.25 |
M112-RM
M112-SM |
U8400034
U8400035 U8400033 |
| M112H-RM** | U8400033 | |||
| 10 | 3 | 0.125 | M1016 | U8400015 |
| 20 | 3 | 0.125 | M116-RM | U8400038 |
| M116-SM | U8400039 | |||
| 20 | 3 | 0.125 | M116H-RM** | U8400037 |
*These transducers can only be used with the High Penetration software option.
**Use with spring loaded holder.
Sonopen® Transducers
The Sonopen transducer has a replaceable delay line that is tapered to a small contact area. This transducer makes reliable thickness measurements in applications such as turbine blades and tight radii on plastic containers.
Sonopen - 15 MHz, 3 mm (0.125 in.) transducer
| Straight Handle | Right Angle Handle | 45° Handle | |||
| Part |
Item
Number | Part |
Item
Number | Part |
Item
Number |
| V260-SM | U8411019 | V260-RM | U8411018 | V260-45 | U8411017 |
Sonopen - Replaceable Delay Lines
| Tip Diameter | Part | Item
Number | |
| mm | inches | ||
| 2.0 | 0.080 | DLP-3 | U8770086 |
| 1.5 | 0.060 | DLP-302 | U8770088 |
| 2.0 | 0.080 | DLP-301† | U8770087 |
†High temperature delay for use up to 175°C (350°F)
Immersion Transducers
Panametrics Microscan immersion transducers are designed to transmit and receive ultrasound in water. Thickness measurements by immersion technique are often preferred when the test piece has a complex geometry or in on-line applications. Typical off-line applications include wall thickness measurements on small diameter plastic or metal tubing, scanned or rotary measurements and thickness measurements on sharply curved parts. Transducer focusing may be necessary depending on the application.
| Frequency (MHz) | Element Diameter | Transducer |
| |
| mm | in. | |||
| 2.25 | 13 | 0.50 | M306-SU | U8410027 |
| 5.0 | 13 | 0.50 | M309-SU | U8420001 |
| 5.0 | 6 | 0.25 | M310-SU | U8420004 |
| 10 | 6 | 0.25 | M312-SU | U8420008 |
| 15 | 6 | 0.25 | M313-SU | U8420009 |
| 20 | 3 | 0.125 | M316-SU | U8420011 |
RBS-1 Immersion Tank
The RBS-1 immersion tank is designed to simplify ultrasonic thickness measurements using immersion techniques.
Delay Line Transducers
Microscan delay line transducers provide excellent performance on very thin materials, at elevated temperatures,or with applications that require a high degree of thickness resolution.
| Freq.
(MHz) | Element
Diameter | Transducer |
| Holders | Item Number | |
| mm | inches | |||||
| 0.5 | 25 | 1.00 | M2008* | U8415001 | - | - |
| 2.25 | 13 | 0.50 | M207-RB | U8410017 | - | - |
| 5.0 | 13 | 0.50 | M206-RB | U8410016 | - | - |
| 5.0 | 6 | 0.25 | M201-RM | U8410001 | - | - |
| 5.0 | 6 | 0.25 | M201H-RM | U8411030 | 2127 | U8770408 |
10 | 6 | 0.25 | M202-RM | U8410003 | - | - |
| M202-SM | U8410004 | |||||
| 10 | 6 | 0.25 | M202H-RM | U8507023 | 2127 | U8770408 |
10 |
| 0.125 | M203-RM | U8410006 | - | - |
| M203-SM | U8410007 | |||||
20 | 3 | 0.125 | M208-RM | U8410019 | - | - |
| M208-SM | U8410020 | |||||
| 20 | 3 | 0.125 | M208H-RM | U8410018 | 2133 | U8770412 |
| 20 | 3 | 0.125 | M2055** | U8415013 | - | - |
| 30 | 6 | 0.25 | V213-BC-RM** | U8411022 | - | - |
*These transducers can only be used with the High Penetration software option.
**Delay line is not replaceable on these transducers.
Replaceable Delay Lines
Delay lines function as a protective buffer between the surface of the test piece and the transducer element.
Element
| Delay Line | Maximum Thickness
Measurement Limit* | |||||||
| mm | inches | Part | Item
Number | Steel - Mode 2 | Steel - Mode 3 | Plastic - Mode 2 | |||
| mm | inches | mm | inches | mm | inches | ||||
| 13 | 0.50 | DLH-2 | U8770062 | 25 | 1.0 | 13 | 0.5 | 13 | 0.5 |
| 6 | 0.25 | DLH-1 | U8770054 | 25 | 1.0 | 13 | 0.5 | 13 | 0.50 |
| 3 | 0.125 | DLH-3 | U8770069 | 13 | 0.5 | 5 | 0.2 | 5 | 0.2 |
Couplants
Liquid couplant is almost always necessary to provide acoustic coupling between the transducer and the test piece. We offer various types of couplants to suit virtually all applications.
Calibration Test Blocks
Test blocks are necessary for the calibration of ultrasonic thickness gages and should be used to maintain and verify the accuracy, dependability, and reliability of ultrasonic measurements. Blocks are held to tighter tolerances than stated in ASTM E797 code. Metric test blocks are available.
Transducer Cables
A wide selection of transducer cables suitable for all ultrasonic thickness gaging instrumentation.
The 45MG offers five code-activated software options that makes it one of the most versatile thickness gages in the industry.
Echo-to-Echo The gage displays the true metal thickness and ignores the thickness of the coating layer, using multiple back-wall echoes:
|
THRU-COAT Technology
|
![]() Auto Echo-to-Echo mode with A-scan |
![]() THRU-COAT mode showing thickness of coating and steel (waveform not activated) |
![]() Manual Echo-to-Echo adjusting the First Echo blank |
![]() THRU-COAT mode with optional waveform |
Single Element Software OptionThe Single Element software option enables you to make very precise thickness measurements at a resolution of up to 0.0001 in. or 0.001 mm. Compatible with single element Microscan transducers ranging from 2.25 MHz to 30 MHz.
|
Single Element High Penetration Software OptionThis option allows you to use low frequency single element transducers (as low as 0.5 MHz) to measure thick or highly attenuating materials such as rubber, fiberglass, castings, and composites. Included is the Single Element option.
|
The 45MG has a full-featured internal bidirectional alphanumeric data logger that is designed to easily store and transfer thickness readings and waveform data. The data logger option includes the GageView™ Interface program. Data Logger Option
|
GageView Interface Program
|
This optional Live A-scan mode allows users to view the ultrasound waveform (or A-scan) directly on the gage's display, verify the thickness measurement, and make manual adjustments to gain and blanking settings to maximize measurement performance in challenging applications. This helpful option features Manual Gain Adjust, Extended Blanking, First Echo Blank, Range, and Delay.
| Measurements | |
| Dual element transducer measurement mode | Time interval from a precision delay after the excitation pulse to the first echo |
| Echo-to-Echo (optional) | Time interval between two successive back-wall echoes to eliminate paint or coating thickness |
| THRU-COAT® measurement (optional) | Measurement of true metal and coating thicknesses with a single back-wall echo (with D7906-SM, D7906-RM, and D7908 transducers) |
| Single element transducer measurement modes (optional) |
Mode 1: Time interval between the excitation pulse and the first back-wall echo
Mode 2: Time interval between the delay line echo and the first back-wall echo (with delay or immersion transducers) Mode 3: Time interval between successive back-wall echoes following the first interface echo after the excitation pulse (with delay line or immersion transducers) |
| Thickness range | 0.080 mm to 635 mm (0.003 in. to 25.0 in.) depending on material, transducer, surface conditions temperature, and selected configuration (Full range requires single element option) |
| Material velocity range | 0.508 mm/μs to18.699 mm/μs (0.020 in./μs to 0.7362 in./μs) |
| Resolution (selectable) |
Low: 0.1 mm (0.01 in.)
Standard: 0.01 mm (0.001 in.) Single Element option: 0.001 mm (0.0001 in.) |
| Transducer frequency range | Standard: 2.25 MHz to 30 MHz (-3 dB) High Penetration (Single Element option): 0.50 MHz to 30 MHz (-3 dB) |
| General | |
| Operating temperature range | -10 °C to 50 °C (14 °F to 122 °F) |
| Keypad | Sealed, color-coded keypad with tactile and audible feedback |
| Case | Impact-resistant and water-resistant, gasketed case with sealed connectors. Designed for IP67. |
| Dimensions (W x H x D) | Overall: 91.1 mm x 162 mm x 41.1 mm (3.59 in. x 6.38 in. x 1.62 in) |
| Weight | 430.9 g (0.95 lb) |
| Power Supply | 3 AA batteries/USB power supply |
| Battery life operating time |
3 AA alkaline: 20 to 21 hours
3 AA NiMH: 22 to 23 hours AA Lithium-ion: 35 to 36 hours |
| Standards | Designed for EN15317 |
| Display | |
| Color transflective QVGA display | Liquid crystal display, display area 54.61 mm x 41.15 mm (2.15 in. x 1.62 in.) |
| Rectification | Full wave, RF, half-wave positive, or half-wave negative (Waveform option) |
| Inputs/Outputs | |
| USB | 2.0 client |
| Memory card | Maximum capacity: 2 GB removable MicroSD memory card |
| Internal Data Logger (Optional) | |
| Data logger | The 45MG identifies, stores, recalls, clears, and transmits thickness readings, waveform images, and gage configuration information through USB or MicroSD. |
| Capacity | 475,000 thickness measurements or 20,000 waveforms with thickness measurements |
| File names, IDs, and comments | 32-character file names and 20-character alphanumeric location codes with four comments per location |
| File structure | Six standard or custom application-specific file structures |
| Reports | On-gage reporting of summary with statistics, Min./Max. |
45MG Ultrasonic Thickness Gage:
|
The 45MG is an advanced ultrasonic thickness gage packed with standard measurement features and software options. This unique instrument is compatible with the complete range of Olympus dual element and single element thickness gage transducers, making this innovative instrument an all-in-one solution for virtually every thickness gage application.
Standard FeaturesIn its basic configuration the 45MG is a simple and straightforward gage that requires minimal operator training to tackle most common thickness gaging applications. With additional optional software options and transducers however, the 45MG can become significantly more advanced and take on applications well beyond that of a typical entry-level gage. Furthermore, most options are available individually at the time of purchase or can be added in the future as your needs change.
| Optional FeaturesFrom a simple corrosion gage to a multi-purpose precision thickness gage with only a few key strokes. The 45MG offers five code-activated software options that makes it one of the most versatile thickness gages in the industry.
|
Built for Tough Environments
|
![]() Indoor display setting, optional A-scan mode |
Designed for Easy Operation
|
|
This self-guided web tutorial provides an introduction to the theory and practice of ultrasonic thickness gaging.