| Inverted Metallurgical Microscope GX71 Specifications | |||
| Optical System | UIS2 Optical System (Infinity-corrected) | ||
| Microscope Frame | Observation Method | BF/DF/DIC/KPO*/FL | |
| Reflected/Transmitted | Reflected/Transmitted | ||
| Illuminator | 6-unit Turret Switching | ||
| Illumination System | Reflected Light | 100 W Halogen/100 W Mercury/75 W Xenon | |
| Transmitted Light | 100 W Halogen | ||
| Focus | Motorized /Manual | Manual Revolving Nosepiece Up/Down Movement (Stage Stationary Type) | |
| Stroke | 9 mm | ||
| Resolution/Fine Adjustment Sensitivity | Fine Stroke per Rotation 0.1 mm | ||
| Revolving Nosepiece | Motorized Type |
Sextuple for BF/DIC
Quintuple for BF/DF/DIC | |
| Manual Type |
Centerable Quadruple for BF/DIC
Sextuple for BF/DIC Quintuple for BF/DF Quintuple for BF/DF/DIC Centerable Quintuple for BF/DF/DIC Sextuple for BF/DF/DIC | ||
| Medium Variable Magnification | Zoom Incorporated (1x-2x) | ||
| Camera Port | Front Port (Reversed Image), Side Port (Reversed Image) | ||
| Stage | Stroke | 50(X)x50(Y)mm | |
| Observation Tube | Standard Field (Field Number 18) | Inverted Image | - |
| Standard Field (Field Number 20) | - | ||
| Wide Field (Field Number 22) | Inverted Image | - | |
| Erect Image | - | ||
| Super Wide Field (Field Number 26.5) | Inverted Image | Binocular/Trinocular Observation Tube | |
| Erect Image | - | ||
| Option | Transmitted Light Polarization Observation Unit | ||
| Dimensions | 280(W)x748(D)x445(H)mm | ||
| Weight | 38 kg (in Standard Combination) | ||
| Remark | *Simple Polarized Light Observation | ||
The GX71 inverted microscope remains one of the most sought-after core research metallographs in use today. Capable of numerous image forming techniques with UIS2 objectives, the GX71 is the workhorse that will provide years of reliability.
![]() Image Forming Mirror Turret |
To handle the diversity of incoming samples and their unique analysis requirements the GX71 implements the largest variety of image forming techniques of all the Olympus inverted metallographs. Brightfield, darkfield, DIC, simple polarization, and fluorescence are available for spot-on investigations. Housed in a dust free turret a selection of mirror cubes can be conveniently and quickly rotated from one position to another. |
Continuous zoom or selectable increments allow images to be viewed at higher magnifications for added inspection versatility and/or required test and inspection standards.
![]() Magnification Changer |
![]() Zoom In/Out Function |
![]() 26.5mm Viewfield Compatible Observation Tubes |
Scan large areas for sample integrity, or defects and irregularities with the 26.5mm view-field offered with the GX-71 system. |
The use of motorized components can save time and cut costs when large quantities of samples require analysis. A single handset is available to quickly control the rotation of objectives. For higher levels of speed and analysis, Stream Image Analysis Software will manage additional components such as the motorized filter wheel and automated scanning stages.

Motorized Components and PC control
UIS2 optics delivers bright, sharp, high-resolution images suitable for all observation methods: brightfield, darkfield, differential interference contrast, polarization, and fluorescence. Designed with specific wave front aberration controls and specialty coatings for color fidelity, UIS2 optics ensure images are true to form and highly resolved.
| Example Observation Images | ||
![]() Brightfield |
![]() Darkfield |
![]() DIC |
![]() Simple Polarization |
![]() Fluorescence |
|
| Diverse Lineup Allows Selections According to the Purpose | |
| MPLAPON | Plan Apochromat Objective Lens Series |
| MPLFLN | Semi Apochromat Objective Lens Series for Brightfield |
| MPLFLN-BD | Semi Apochromat Objective Lens Series for Brightfield and Darkfield |
| MPLFLN-BDP | Semi Apochromat Objective Lens Series for Brightfield and Darkfield |
| LMPLFLN | Long WD Semi Apochromat Objective Lens Series for Brightfield |
| LMPLFLN-BD | Long WD Semi Apochromat Objective Lens Series for Brightfield and Darkfield |
| MPLN | Plan Achromat Objective Lens Series for Brightfield |
| MPLN-BD | Plan Achromat Objective Lens Series for both Brightfield and Darkfield |
| SLMPLN | Super Long WD Plan Achromat Objective Lens Series |
| LCPLFLN-LCD | Long WD Semi Apocromatic Objective Lens Series for LCD |
> Click here for details about UIS2 objective lenses
Our full line of digital cameras provide high resolution viewing and fast image transfer while our advanced OLYMPUS Image Analysis Software empowers users and provides all the tools required for today's most complex metallurgical requirements. Choose from Extended Measurements, Standard Metallography and Advanced Metallography application specific modules (over a dozen application specific routines) and automatically populate data and create reports in compliance with the most popular ASTM and ISO specifications, all with just a few clicks of the mouse.
> Click here for the Olympus' lineup of digital cameras
> Click here for the Olympus' lineup of software options
A transmitted light illuminator can be attached to the back of the microscope body, enabling observation of transparent specimens and powders.
Copyright 2013 OLYMPUS CORPORATION, All rights reserved. Terms Of Use | Privacy Statement