Delay Line, Water Column Spot-Weld Transducer. 15 MHz, 0.118 in./3.0 mm element diameter. For use with DLCW-1003 Water Column or SWDL-30 / SWDL-32 Delay Line & SWRR-1 Retaining Ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 15 MHz, 0.138 in./3.5 mm element diameter. For use with DLCW-2003 water column or SWDL-35 / SWDL-37 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 15 MHz, 0.157 in./4.0 mm element diameter. For use with DLCW-2003 water column or SWDL-40 / SWDL-42 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 15 MHz, 0.177 in./4.5 mm element diameter. For use with DLCW-2003 water column or SWDL-45 / SWDL-47 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay Line, Water Column Spot-Weld Transducer. 15 MHz, 0.197 in./5.0 mm Element Diameter. For use with DLCW-2003 Water Column or SWDL-50 / SWDL-52 Delay Line & SWRR-2 Retaining Ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 15 MHz, 0.217 in./5.5 mm element diameter. For use with DLCW-2003 water column or SWDL-55 / SWDL-57 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 15 MHz, 0.236 in./6.0 mm element diameter. For use with DLCW-2003 water column or SWDL-60 / SWDL-62 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay Line, Water Column Spot-Weld Transducer. 15 MHz, 0.256 in./6.5 mm Element Diameter. For use with DLCW-3003 Water Column or SWDL-65/ SWDL-67 Delay Line & SWRR-3 Retaining Ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 15 MHz, 0.315 in./8.0 mm element diameter. For use with DLCW-3003 water column or SWDL-80 / SWDL-82 delay line & SWRR-3 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay Line, Water Column Spot-Weld Transducer. 15 MHz, 0.98 in./2.5 mm Element Diameter. For use with DLCW-1003 Water Column or SWDL-325/ SWDL-27 Delay Line & SWRR-1 Retaining Ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 20 MHz, 0.098 in./ 2.5 mm element diameter. For use with DLCW-1003 water column or SWDL-25 / SWDL-27 delay line & SWRR-1 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 20 MHz, 0.118 in./ 3.0 mm element diameter. For use with DLCW-1003 water column or SWDL-30 / SWDL-32 delay line & SWRR-1 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 20 MHz, 0.138 in./3.5 mm element diameter. For use with DLCW-2003 water column or SWDL-35 / SWDL-37 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 20 MHz, 0.157in./4.0 mm element diameter. For use with DLCW-2003 water column or SWDL-40 / SWDL-42 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 20 MHz, 0.177 in./4.5 mm element diameter. For use with DLCW-2003 water column or SWDL-45 / SWDL-47 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 20MHz, 0.197 in./5.0 mm element diameter. For use with DLCW-2003 water column or SWDL-50 / SWDL-52 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 20 MHz, 0.217 in./5.5 mm element diameter. For use with DLCW-2003 water column or SWDL-55 / SWDL-57 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 20 MHz, 0.236 in./6.0 mm element diameter. For use with DLCW-2003 water column or SWDL-60 / SWDL-62 delay line & SWRR-2 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote
Delay line / water column Spot-Weld Transducer. 20 MHz, 0.256 in./6.5 mm element diameter. For use with DLCW-3003 water column or SWDL-65 / SWDL-67 delay line & SWRR-3 retaining ring (not included). Includes Test Form CertificateBuy NowBuy NowRequest a Quote