1 00:00:10,156 --> 00:00:12,886 The Olympus STM7 microscope 2 00:00:12,888 --> 00:00:15,480 is designed for high-accuracy metrology 3 00:00:15,481 --> 00:00:19,505 and precise measurements in material science. 4 00:00:19,506 --> 00:00:21,286 With a basic configuration, 5 00:00:21,288 --> 00:00:23,915 often known as a tool maker’s microscope, 6 00:00:23,916 --> 00:00:26,100 an operator can quickly take measurements 7 00:00:26,101 --> 00:00:30,018 to see variations in production or tooling wear. 8 00:00:30,020 --> 00:00:33,265 STM7 measuring software can be added 9 00:00:33,266 --> 00:00:36,491 enabling operators to take complex measurements, 10 00:00:36,493 --> 00:00:38,285 create testing routines, 11 00:00:38,286 --> 00:00:40,833 and efficiently deliver pass / fail results 12 00:00:40,835 --> 00:00:45,215 for components such as printed circuit boards and wafers. 13 00:00:45,216 --> 00:00:48,740 The STM7 has a modular design. 14 00:00:48,741 --> 00:00:51,385 Customization for sample size, lighting, 15 00:00:51,386 --> 00:00:56,780 and motorization can be addressed by a wide variety of available options. 16 00:00:56,781 --> 00:00:58,916 In a tool maker’s configuration, 17 00:00:58,918 --> 00:01:03,033 operators simply place their sample on the STM7’s stage 18 00:01:03,035 --> 00:01:06,098 and locate the feature they wish to measure. 19 00:01:06,100 --> 00:01:08,810 Moving across the feature to an end point, 20 00:01:08,811 --> 00:01:13,081 the display shows the distance measured in all 3 axes. 21 00:01:13,083 --> 00:01:15,366 Olympus offers software to enhance 22 00:01:15,368 --> 00:01:18,830 the microscope’s measuring capabilities. 23 00:01:18,831 --> 00:01:21,563 Using the software’s edge detection function 24 00:01:21,565 --> 00:01:24,771 can simplify and speed up measurements. 25 00:01:24,773 --> 00:01:28,126 In this example, the software detects five points 26 00:01:28,128 --> 00:01:29,951 while the user quickly moves around 27 00:01:29,953 --> 00:01:33,770 the sides of the rectangle and obtains results. 28 00:01:33,771 --> 00:01:36,498 Additional edge detection tools are available 29 00:01:36,500 --> 00:01:39,468 including circle edge detection, which provides 30 00:01:39,470 --> 00:01:44,181 up to 99 data points for better measurement accuracy. 31 00:01:44,183 --> 00:01:48,473 Manufacturers often create hundreds of components an hour. 32 00:01:48,475 --> 00:01:51,430 Periodic sample testing must be regularly performed 33 00:01:51,431 --> 00:01:57,370 to ensure quality. 34 00:01:57,371 --> 00:02:00,213 The software guides users to each measurement point 35 00:02:00,215 --> 00:02:05,508 to ensure the correct measurements are taken. 36 00:02:05,510 --> 00:02:07,748 The software compares measurement results 37 00:02:07,750 --> 00:02:09,681 to known design tolerances 38 00:02:09,683 --> 00:02:12,831 and automatically displays any failure in red 39 00:02:12,833 --> 00:02:16,318 so users know immediately if there is an issue. 40 00:02:16,320 --> 00:02:20,046 Stages for the STM7 range from 50×50 41 00:02:20,048 --> 00:02:23,323 to 300×300 mm and support objects 42 00:02:23,325 --> 00:02:25,621 as large as a 12 inch wafer 43 00:02:25,623 --> 00:02:28,835 or a component weighing up to 30 lbs. 44 00:02:28,836 --> 00:02:31,870 Stages can be equipped with a rotatable stage plate 45 00:02:31,871 --> 00:02:35,641 to simplify measuring in a single axis. 46 00:02:35,643 --> 00:02:37,633 By utilizing the clutch feature, 47 00:02:37,635 --> 00:02:39,355 the stage can be moved quickly 48 00:02:39,356 --> 00:02:42,186 for greater distance measurements. 49 00:02:42,188 --> 00:02:44,678 The STM7 offers both manual 50 00:02:44,680 --> 00:02:47,205 and motorized height measurement. 51 00:02:47,206 --> 00:02:49,270 To improve reproducibility, 52 00:02:49,271 --> 00:02:53,385 a focus navigator can be added to the system. 53 00:02:53,386 --> 00:02:54,933 With a motorized frame, 54 00:02:54,935 --> 00:02:58,098 a convenient hand switch controls all height movement 55 00:02:58,100 --> 00:03:00,303 while the Z-limit option keeps the objective 56 00:03:00,305 --> 00:03:03,640 lens from hitting the sample. 57 00:03:03,641 --> 00:03:07,841 A laser autofocus can be paired with the motorized frame. 58 00:03:07,843 --> 00:03:11,198 While moving across the sample in the X or Y axis, 59 00:03:11,200 --> 00:03:14,221 the laser autofocus controls the motorized height 60 00:03:14,223 --> 00:03:16,971 to keep the sample in focus. 61 00:03:16,973 --> 00:03:18,691 Integrated LED lighting 62 00:03:18,693 --> 00:03:21,405 supports controls for Brightfield or Darkfield 63 00:03:21,406 --> 00:03:23,210 reflected light observation, 64 00:03:23,211 --> 00:03:25,275 transmitted light observation, 65 00:03:25,276 --> 00:03:27,880 and the focus navigator option. 66 00:03:27,881 --> 00:03:30,338 For highly reflective surfaces, 67 00:03:30,340 --> 00:03:34,653 users can add a polarizer and rotatable analyzer. 68 00:03:34,655 --> 00:03:36,546 Adding a DIC Prism 69 00:03:36,548 --> 00:03:41,110 improves the visibility of minor surface changes. 70 00:03:41,111 --> 00:03:44,323 The Olympus STM7 measuring microscope 71 00:03:44,325 --> 00:03:47,155 is a versatile, high performance instrument 72 00:03:47,156 --> 00:03:49,956 which provides operators three-dimensional measurements 73 00:03:49,958 --> 00:03:52,725 with sub-micron precision. 74 00:03:52,726 --> 00:03:55,735 Olympus Application Specialists and Service Engineers 75 00:03:55,736 --> 00:03:58,148 are available to conduct user training 76 00:03:58,150 --> 00:04:02,263 and provide industry traceable calibrations. 77 00:04:02,265 --> 00:04:06,303 For more information on Olympus Industrial Microscope solutions 78 00:04:06,305 --> 00:04:08,551 contact your local representative 79 00:04:08,553 --> 00:04:16,743 or visit our website at www.olympus-ims.com.