1 00:00:02,170 --> 00:00:04,838 The RollerFORM phased array wheel probe from Olympus 2 00:00:04,838 --> 00:00:08,050 is designed for zero degree C-scan inspection 3 00:00:08,050 --> 00:00:12,222 of aerospace composites, aluminum panels and wind turbine blades 4 00:00:12,222 --> 00:00:14,557 to measure thickness and material loss 5 00:00:14,557 --> 00:00:17,768 and detect and size delamination and disbonds 6 00:00:17,768 --> 00:00:21,147 and detect and quantify internal porosity. 7 00:00:21,147 --> 00:00:26,152 Combined with the OmniScan SX, MX2, or X3 flaw detector, 8 00:00:26,152 --> 00:00:29,655 the Olympus RollerFORM scanner is an affordable, easy-to-implement 9 00:00:29,655 --> 00:00:34,535 portable alternative to immersion tank and thru-transmission inspection systems 10 00:00:34,535 --> 00:00:38,247 for flat, convex, or narrow surfaces. 11 00:00:38,247 --> 00:00:40,958 The acoustic tire contains the phased array probe 12 00:00:40,958 --> 00:00:44,003 and creates a 25 mm delay line in water 13 00:00:44,003 --> 00:00:49,717 for smooth scanning and optimized C-scan inspection of composite components. 14 00:00:49,717 --> 00:00:51,510 Key features include: 15 00:00:51,510 --> 00:00:57,850 Swappable 1, 3.5, and 5 MHz Olympus phased array probes. 16 00:00:57,850 --> 00:00:59,768 Two models are available: 17 00:00:59,768 --> 00:01:03,105 The original RollerFORM scanner’s 64-element probe 18 00:01:03,105 --> 00:01:06,400 provides a beam coverage of up to 51 millimeters 19 00:01:06,400 --> 00:01:10,488 and the RollerFORM XL scanner’s 128-element probe 20 00:01:10,488 --> 00:01:14,450 provides up to 128 mm of coverage. 21 00:01:14,450 --> 00:01:18,788 A low-attenuation, impedence-matched transparent tire for the probe coupling 22 00:01:18,788 --> 00:01:24,502 allows fast, efficient C-scan acquisition with only a mist of water. 23 00:01:24,502 --> 00:01:27,713 Transparent tire material lets you see any bubbles, 24 00:01:27,713 --> 00:01:31,927 which can be cleared quickly through the bubble trap on one side. 25 00:01:31,927 --> 00:01:34,970 Waterproof integrated quadrature encoder. 26 00:01:34,970 --> 00:01:38,517 Integrated laser guide for precision line scanning. 27 00:01:38,517 --> 00:01:44,563 Integrated button on the scanner handle for raster scan indexing or “Clicker” function. 28 00:01:44,563 --> 00:01:47,525 Integrated programmable button on the scanner handle 29 00:01:47,525 --> 00:01:53,615 for start acquisition, save data, pause\resume, or preset encoder. 30 00:01:53,615 --> 00:01:56,993 Integrated cable management and umbilical cover. 31 00:01:56,993 --> 00:02:00,747 Height adjustable middle wheel and skid plate for stabilization 32 00:02:00,747 --> 00:02:03,875 when scanning narrow or curved components. 33 00:02:03,875 --> 00:02:05,793 The Olympus RollerFORM scanner 34 00:02:05,793 --> 00:02:10,882 can be used with any OmniScan SX, MX2, and X3 phased array instrument 35 00:02:10,882 --> 00:02:12,800 while the RollerFORM XL scanner 36 00:02:12,800 --> 00:02:18,848 can be used with 128 element OmniScan MX2 and X3 flaw detectors. 37 00:02:18,848 --> 00:02:21,808 The RollerFORM encoder is connected to the instrument 38 00:02:21,808 --> 00:02:25,145 with a waterproof industrial grade LEMO connector. 39 00:02:25,145 --> 00:02:26,857 The RollerFORM phased array probe 40 00:02:26,857 --> 00:02:30,193 is connected to the instrument with the quick latch connector. 41 00:02:30,193 --> 00:02:33,237 It is autodetected by the OmniScan flaw detector, 42 00:02:33,237 --> 00:02:37,908 which will update the phased array configuration for the installed probe. 43 00:02:37,908 --> 00:02:41,787 Load the preconfigured setup file provided with the RollerFORM unit 44 00:02:41,787 --> 00:02:44,457 by selecting the correct model. 45 00:02:44,457 --> 00:02:47,877 Configure the UT and gate parameters for the C-scan inspection 46 00:02:47,877 --> 00:02:52,673 that will change with a different probe, material, or thickness. 47 00:02:52,673 --> 00:02:56,260 Alternatively, the scanning parameters can be quickly set up 48 00:02:56,260 --> 00:03:01,140 using the OmniScan X3 flaw detector’s onboard scanner library. 49 00:03:01,140 --> 00:03:05,312 The RollerFORM inspection is configured for either a single one line scan 50 00:03:05,312 --> 00:03:07,313 using only the scanner’s encoder, 51 00:03:07,313 --> 00:03:09,648 or a 2-axis raster scan 52 00:03:09,648 --> 00:03:12,693 using the encoder and button on the RollerFORM handle 53 00:03:12,693 --> 00:03:16,072 to automatically index multiple line scans. 54 00:03:16,072 --> 00:03:21,535 Define the area of the inspection in the Scan/Area menu in each axis. 55 00:03:21,535 --> 00:03:25,290 The index axis is controlled by the button on the RollerFORM handle 56 00:03:25,290 --> 00:03:30,628 and is configured for the width of the probe plus any overlap as desired. 57 00:03:30,628 --> 00:03:34,257 This parameter is also a function of the phased array setup 58 00:03:34,257 --> 00:03:37,052 and is autocalculated by the software. 59 00:03:37,052 --> 00:03:40,347 Prior to inspection the RollerFORM scanner’s acoustic tire 60 00:03:40,347 --> 00:03:43,182 must be filled with water and free of bubbles. 61 00:03:43,182 --> 00:03:47,562 Distilled, desalinized water is best and it is highly recommended 62 00:03:47,562 --> 00:03:50,690 that the water chamber be filled the day prior to inspection 63 00:03:50,690 --> 00:03:54,818 to allow the water to de-gas and saturate the tire material. 64 00:03:54,818 --> 00:04:00,073 Open the out valve and insert the water feed tube over the in valve. 65 00:04:00,073 --> 00:04:06,080 Pump water slowly with the out valve at the highest position until the tire is filled. 66 00:04:06,080 --> 00:04:12,628 Tap or squeeze the tire gently while moving the RollerFORM scanner side to side to clear bubbles. 67 00:04:12,628 --> 00:04:15,965 Any bubbles present after the tire is initially cleared 68 00:04:15,965 --> 00:04:20,595 can be removed by the bubble trap on the right side of the tire assembly. 69 00:04:20,595 --> 00:04:24,890 The water chamber is filled properly when there is a gap of approximately 2 mm 70 00:04:24,890 --> 00:04:28,102 between the plastic wheel and the component surface 71 00:04:28,102 --> 00:04:31,230 while no pressure is being applied to the RollerFORM handle. 72 00:04:31,230 --> 00:04:33,817 Adjust the middle wheel and lock into place 73 00:04:33,817 --> 00:04:37,778 to conform the RollerFORM to the component surface if required. 74 00:04:37,778 --> 00:04:42,325 This enables the inspector to apply pressure without distorting the tire. 75 00:04:42,325 --> 00:04:44,702 Pre-wet the RollerFORM tire thoroughly 76 00:04:44,702 --> 00:04:48,957 and apply light water with a spray bottle over the area to be inspected. 77 00:04:48,957 --> 00:04:54,378 Make any adjustments to the phased array or UT configuration and save the setup file. 78 00:04:54,378 --> 00:04:59,467 Position the scanner at the start of the inspection and press the start acquisition button. 79 00:04:59,467 --> 00:05:03,512 The start acquisition button on the RollerFORM handle is programmable 80 00:05:03,512 --> 00:05:08,768 and by default will clear the C-scan and preset the encoders. 81 00:05:08,768 --> 00:05:14,190 Roll the RollerFORM to the end of the first line scan. 82 00:05:14,190 --> 00:05:26,077 Press the indexer button on the RollerFORM to preset the encoder to the next line scan position. 83 00:05:26,077 --> 00:05:31,623 The raster scan is configured for either a series of one-line scans in the same direction 84 00:05:31,623 --> 00:05:36,420 or scanning back and forth to complete the C-scan. 85 00:05:36,420 --> 00:05:40,425 When the inspection is complete select pause. 86 00:05:40,425 --> 00:05:43,970 Review the C-scan and save the data file. 87 00:05:43,970 --> 00:05:47,682 The data can now be analyzed on the OmniScan flaw detector, 88 00:05:47,682 --> 00:05:53,020 or on a computer using OmniPC™ or WeldSight™ software. 89 00:05:53,020 --> 00:05:58,108 www.olympus-ims.com