1 00:00:05,216 --> 00:00:08,659 Introducing the new Nortec 600 high-performance digital 2 00:00:08,661 --> 00:00:11,729 eddy current portable flaw detector. 3 00:00:11,731 --> 00:00:13,768 Hello, my name is Tommy Bourgelas 4 00:00:13,769 --> 00:00:16,258 and I am the product manager of eddy current 5 00:00:16,260 --> 00:00:19,744 and bond testing products with Olympus. 6 00:00:19,746 --> 00:00:23,374 I would like to introduce you to Olympus’ latest development 7 00:00:23,376 --> 00:00:25,723 of next-generation, high-performance 8 00:00:25,724 --> 00:00:28,308 digital eddy current portable flaw detectors, 9 00:00:28,310 --> 00:00:31,635 the NORTEC 600. 10 00:00:31,636 --> 00:00:34,856 The NORTEC 600 is a rugged, field ready instrument 11 00:00:34,858 --> 00:00:39,306 that features a vibrant display to accommodate any lighting condition. 12 00:00:39,308 --> 00:00:42,305 It has a completely redesigned user interface 13 00:00:42,306 --> 00:00:45,969 that is very intuitive for any level of user. 14 00:00:45,971 --> 00:00:50,844 It also offers a complete archiving and reporting solution. 15 00:00:50,846 --> 00:00:55,201 The NORTEC 600 comes in 4 models to suit any need. 16 00:00:55,203 --> 00:00:58,673 From its basic, conductivity, rotating scanner, 17 00:00:58,674 --> 00:01:02,856 or dual frequency configuration, the NORTEC 600 is packed 18 00:01:02,858 --> 00:01:05,566 with innovative and exciting features 19 00:01:05,568 --> 00:01:08,428 to solve all common applications. 20 00:01:08,429 --> 00:01:12,348 The instrument is designed to meet the requirements of IP66 21 00:01:12,349 --> 00:01:17,130 and is also EN15548 compliant. 22 00:01:17,131 --> 00:01:20,333 It is delivered with a factory -installed hand strap 23 00:01:20,334 --> 00:01:22,804 for maximum maneuverability, 24 00:01:22,806 --> 00:01:26,239 and can be attached to a 4-point optional chest harness 25 00:01:26,241 --> 00:01:30,041 or used with an optional soft case. 26 00:01:30,043 --> 00:01:32,168 Its high-friction rear stand allows 27 00:01:32,169 --> 00:01:36,561 either hanging the instrument or laying it horizontally. 28 00:01:36,563 --> 00:01:38,774 The NORTEC 600 has a USB port 29 00:01:38,776 --> 00:01:41,168 to transfer files to a computer, 30 00:01:41,169 --> 00:01:44,431 an on-board micro-SD memory card 31 00:01:44,433 --> 00:01:49,901 a VGA output and a complete I/O connector 32 00:01:49,903 --> 00:01:52,411 Its new, higher-capacity battery 33 00:01:52,413 --> 00:01:55,568 allows over 10 hours of normal operation 34 00:01:55,570 --> 00:02:01,163 and from 6 to nearly 8 hours of rotating scanner operation. 35 00:02:01,164 --> 00:02:04,873 The NORTEC 600 features a 16-way LEMO connector 36 00:02:04,874 --> 00:02:09,278 that maintains compatibility with 12-way LEMO connectors 37 00:02:09,280 --> 00:02:12,714 by using an optional adaptor cable. 38 00:02:12,716 --> 00:02:15,984 It also maintains compatibility with existing Olympus 39 00:02:15,986 --> 00:02:18,161 Powerlink eddy current probes, 40 00:02:18,163 --> 00:02:21,488 as well as other major probe and scanner suppliers. 41 00:02:21,489 --> 00:02:24,726 The NORTEC 600 also features a BNC connector 42 00:02:24,728 --> 00:02:27,443 featuring a new automatic internal balancing 43 00:02:27,444 --> 00:02:30,523 for single-coil absolute probes. 44 00:02:30,525 --> 00:02:33,939 The NORTEC 600 offers the most brilliant display 45 00:02:33,941 --> 00:02:37,038 in the portable ECT flaw detector market. 46 00:02:37,040 --> 00:02:40,774 No other product matches its signal quality, definition, 47 00:02:40,776 --> 00:02:45,308 resolution and ease of viewing in all lighting conditions. 48 00:02:45,310 --> 00:02:48,131 The instrument features 8 color schemes 49 00:02:48,133 --> 00:02:52,856 including indoor and outdoor display configuration. 50 00:02:52,858 --> 00:02:55,709 To further enhance the signal viewing experience, 51 00:02:55,711 --> 00:02:59,151 the NORTEC 600 features a true FULL SCREEN mode 52 00:02:59,153 --> 00:03:03,728 that can be toggled on and off from all configurations. 53 00:03:03,729 --> 00:03:06,489 Additionally, up to 2 real-time readings 54 00:03:06,491 --> 00:03:09,310 can show various characteristics of the signal, 55 00:03:09,311 --> 00:03:12,984 such as its peak amplitude, phase angle, 56 00:03:12,986 --> 00:03:16,623 and a selection of other configurable readings. 57 00:03:16,625 --> 00:03:19,651 The NORTEC 600 offers the most intuitive, 58 00:03:19,653 --> 00:03:23,300 simple and productive user interface on the market. 59 00:03:23,301 --> 00:03:26,448 This newly-redesigned interface significantly reduces 60 00:03:26,449 --> 00:03:30,273 the learning curve while maintaining a high level of productivity 61 00:03:30,275 --> 00:03:33,676 when inspecting, for any level of user. 62 00:03:33,678 --> 00:03:38,300 The NORTEC 600 user interface features 5 menu keys. 63 00:03:38,301 --> 00:03:42,081 Pressing a menu key toggles between the different menu pages, 64 00:03:42,083 --> 00:03:44,901 for locating parameters easily. 65 00:03:44,903 --> 00:03:48,354 Once a parameter is found, it can be selected 66 00:03:48,356 --> 00:03:50,913 with help of the Parameter keys, 67 00:03:50,914 --> 00:03:55,498 and its value changed by rotating the Smart Knob. 68 00:03:55,499 --> 00:04:00,383 The NORTEC 600 also features a set of 6 Direct Access keys, 69 00:04:00,384 --> 00:04:03,311 in order to speed up the most common operations, 70 00:04:03,313 --> 00:04:07,448 such as adjusting the gains, or phase angle. 71 00:04:07,449 --> 00:04:11,093 The instrument includes several new highly-acclaimed features, 72 00:04:11,094 --> 00:04:14,251 such as the new Application Selection menu. 73 00:04:14,253 --> 00:04:17,338 This menu streamlines the configuration of the instrument 74 00:04:17,339 --> 00:04:21,028 for a given inspection, literally within seconds. 75 00:04:21,029 --> 00:04:23,203 Once an Application has been selected, 76 00:04:23,204 --> 00:04:25,638 only a few parameters need to be changed 77 00:04:25,640 --> 00:04:28,853 in order to calibrate the signals. 78 00:04:28,854 --> 00:04:31,748 Other innovative features include: 79 00:04:31,749 --> 00:04:34,728 The ability to calibrate from frozen signals 80 00:04:34,729 --> 00:04:38,431 which separates the scanning motion from the calibration. 81 00:04:38,433 --> 00:04:40,749 An improved filter system 82 00:04:40,751 --> 00:04:43,881 displaying standard figure 6 signals 83 00:04:43,883 --> 00:04:47,268 for rotary scanner applications. 84 00:04:47,270 --> 00:04:50,818 The All Settings menu which is useful to quickly 85 00:04:50,819 --> 00:04:53,914 configure the instrument from a procedure. 86 00:04:53,916 --> 00:04:56,260 An improved conductivity module 87 00:04:56,261 --> 00:05:00,031 with an easy to use calibration wizard. 88 00:05:00,033 --> 00:05:02,186 An All-in-one display mode, 89 00:05:02,188 --> 00:05:05,053 showing up to 3 configurable traces, 90 00:05:05,054 --> 00:05:07,836 in dual frequency operation. 91 00:05:07,838 --> 00:05:11,258 And Automatic mixing for instant configuration 92 00:05:11,260 --> 00:05:15,764 in applications such as heat exchanger tube testing. 93 00:05:15,766 --> 00:05:20,676 The NORTEC 600 features an easy to use archiving and reporting system. 94 00:05:20,678 --> 00:05:24,560 A single press of the SAVE key instantly creates a file 95 00:05:24,561 --> 00:05:26,788 on the instrument. The instrument can store 96 00:05:26,789 --> 00:05:28,889 up to 500 files. 97 00:05:28,891 --> 00:05:32,016 Each file includes both DATA information 98 00:05:32,018 --> 00:05:35,070 and PROGRAM (SETUP) information 99 00:05:35,071 --> 00:05:39,951 so there is never any disconnect between the programs or data files. 100 00:05:39,953 --> 00:05:43,513 The NORTEC 600 features an on-board file preview 101 00:05:43,515 --> 00:05:45,816 before the files are loaded. 102 00:05:45,818 --> 00:05:48,266 The on-board text editor also allows 103 00:05:48,268 --> 00:05:51,343 renaming files as needed. 104 00:05:51,344 --> 00:05:53,531 Once the inspection is completed 105 00:05:53,533 --> 00:05:57,413 the files can easily be transferred to a computer via the USB cable 106 00:05:57,414 --> 00:06:01,291 and viewed using NORTEC PC software. 107 00:06:01,293 --> 00:06:05,053 In NORTEC PC, signals or parameters can be viewed, 108 00:06:05,054 --> 00:06:09,338 printed, copied, and easily exported into a PDF report 109 00:06:09,339 --> 00:06:11,628 at the touch of a button. 110 00:06:11,630 --> 00:06:15,633 The “PDF all” function comes in particularly handy 111 00:06:15,635 --> 00:06:21,243 to archive all inspection files in a single operation. 112 00:06:21,244 --> 00:06:24,026 With its rugged, field-ready casing 113 00:06:24,028 --> 00:06:26,956 and its vibrant display, the NORTEC 600 114 00:06:26,958 --> 00:06:29,824 is an industry leading eddy current flaw detector. 115 00:06:29,826 --> 00:06:33,155 The intuitive interface and reporting capabilities 116 00:06:33,156 --> 00:06:36,003 of NORTEC PC make the NORTEC 600 117 00:06:36,005 --> 00:06:38,419 the preferred portable eddy current instrument 118 00:06:38,421 --> 00:06:41,276 for any level of user. 119 00:06:41,278 --> 00:06:45,201 For more information on Olympus' eddy current solutions 120 00:06:45,203 --> 00:06:47,515 contact your local representative 121 00:06:47,516 --> 00:06:58,423 or visit us online at www.olympus-ims.com.