1 00:00:09,676 --> 00:00:11,378 Olympus is proud to introduce 2 00:00:11,378 --> 00:00:13,815 two new dual element transducers 3 00:00:13,815 --> 00:00:16,083 for use with the 27MG, 4 00:00:16,083 --> 00:00:20,655 45MG, and 38DL PLUS ultrasonic thickness gages. 5 00:00:20,655 --> 00:00:24,691 The D7912 and D7913 are 10 MHz 6 00:00:24,691 --> 00:00:26,493 dual element transducers 7 00:00:26,493 --> 00:00:32,233 with a small tip diameter of 0.295 in., or 7 mm. 8 00:00:32,233 --> 00:00:34,535 They are designed for making thickness measurements 9 00:00:34,535 --> 00:00:37,371 on thin walled, small diameter tubes and pipes 10 00:00:37,371 --> 00:00:41,175 at temperatures below 125 degrees Fahrenheit 11 00:00:41,175 --> 00:00:43,811 or 50 degrees Celsius. 12 00:00:43,811 --> 00:00:46,546 The thickness measurement range for these transducers 13 00:00:46,546 --> 00:00:50,218 is approximately twenty thousands of an inch to one inch 14 00:00:50,218 --> 00:00:52,653 or zero point five millimeters 15 00:00:52,653 --> 00:00:54,721 to twentyfive point four millimeters 16 00:00:54,721 --> 00:00:57,758 depending on the material and applications. 17 00:00:57,758 --> 00:00:59,826 Use of the instrument’s gain adjustment 18 00:00:59,826 --> 00:01:02,796 may be required to achieve the full thickness range. 19 00:01:02,796 --> 00:01:06,566 The D7913 is a right angle transducer 20 00:01:06,566 --> 00:01:07,935 with a potted cable 21 00:01:07,935 --> 00:01:10,271 and rubber over molded strain relief. 22 00:01:10,271 --> 00:01:12,306 This transducer is great for applications 23 00:01:12,306 --> 00:01:14,708 with limited height requirements. 24 00:01:14,708 --> 00:01:17,545 The D7912 is a straight version 25 00:01:17,545 --> 00:01:20,248 with a potted cable and over molded bell housing 26 00:01:20,248 --> 00:01:22,816 strain relief. 27 00:01:22,816 --> 00:01:26,186 Both the D7912 and D7913 28 00:01:26,186 --> 00:01:28,623 are constructed with a stainless steel case 29 00:01:28,623 --> 00:01:31,125 for excellent wear resistance. 30 00:01:31,125 --> 00:01:33,193 These dual element transducers are designed 31 00:01:33,193 --> 00:01:36,063 to meet the center frequency specification 32 00:01:36,063 --> 00:01:39,633 of EN15317. 33 00:01:39,633 --> 00:01:42,636 The D7912 and the D7913 34 00:01:42,636 --> 00:01:46,373 Along with our lower cost 5 MHz D7910 35 00:01:46,373 --> 00:01:48,743 Are great additions to the Olympus line 36 00:01:48,743 --> 00:01:51,778 of high quality corrosion thickness gage transducers. 37 00:01:51,778 --> 00:01:55,383 For more information, contact your local sales representative 38 00:01:55,383 --> 00:02:01,355 or visit our website at www.olympus-ims.com.