The TRPP 5810 unit is a high-performance remote pulser/preamplifier dedicated to TOFD inspection and compatible with the Olympus scanner line as well as PV-100 and PV-200 weld inspection systems.
This remote pulser/preamplifier provides an optimum signal-to-noise ratio for TOFD inspection by combining a 40 dB preamplifier with a remote high-voltage (200 V) pulse repeater in a single, small enclosure. The TRPP 5810 supports two UT channels, enabling simultaneous inspection with one or two pairs of TOFD probes.
Application
|
The TRPP 5810 can be used as a pulser and/or preamplifier.
TRPP 5810 as a Pulser - Provides an additional pulse gain in order to generate a stronger signal when needed to reveal difficult-to-detect flaws.
TRPP 5810 as a Preamplifier - Provides the additional gain or broadband signal-to-noise enhancement necessary for optimum signal acquisition on thick sections of material exhibiting high ultrasonic attenuation.
- Allow driving of long cables from remotely located sensors.
Pulser - Remote, high-voltage (200 V) pulse repeater
- PRF of up to 10 kHz at 100 ns per channel and up to 20 kHz at 50 ns for a single channel
- Outputs are protected against misuse and bad connection to pulser outputs.
Preamplifier (Receiver) - 40 dB preamplifier
- Accommodates probe frequency range from 1 MHz to 15 MHz.
- Inputs and outputs are protected against misuse and bad connection to pulser outputs.
|
General Features
|
- Withstands pulsed voltages up to 300 V for pulse widths in excess of 500 ns at PRFs up to 10 kHz.
- Dimensions (W×H×L): 57 mm×32 mm×90 mm
- Weight: 300 g
- UT connectors: 8×LEMO (00) female coaxial
- Water/moisture resistance: NEMA 4-IP66 or better. Rustproof.
- Casing material: Aluminum
- Powered by an external 12 VDC source or from instrument.
- Power connector: Compatible with standard Olympus umbilical cables (male Fisher 103 type)
- Red power-on LED indicator
- Operating temperature range: -10 °C to 60 °C
- Storage temperature range: -20 °C to 70 °C
|
Specifications
|

| Pulser | |
Output pulse voltage
|
Fixed, -200 V into 50 Ω load
| |
Output impedance
|
≤6 Ω
| |
Input impedance
|
50 Ω
| |
Maximum PRF, Hz
|
5 kHz @ 100 ns pw, both channels
10 kHz @ 100 ns pw, single channel
20 kHz @ 50 ns pw, single channel
(Maximum duty cycle of 0.1% total)
|

| Preamplifier (Receiver) | |
Voltage gain into 50 Ω load
|
Fixed, 40 dB
| |
Bandwidth (-3 dB)
|
0.5 MHz to 30 MHz
| |
Input-referred noise
|
≤2 nV, with source impedance = 50 Ω
| |
Input/output
|
HV protection ≥ -300 V
| |
Input impedance
|
550 Ω
| |
Output impedance
|
50 Ω
| |
Crosstalk between channels
|
≥70 dB at 10 MHz sine wave
|
|
|
|