Ultrasonic thickness gauging is not just limited to materials at normal (ambient) temperatures. The thickness of a part can be measured even when the surface temperature approaches 900 deg F (500 deg C). In metals, particularly, there may be circumstances when the thickness of the part needs to be measured before the part can be cooled down. Ultrasonic testing has the advantage - just as at normal temperatures - that thickness measurements can be taken from one side of the hot part. Ultrasonics may be the preferred method of measurement even when both sides of the hot metal part are accessible. The reason is that ultrasonic thickness measurements can be made instantly and with very brief contact with the hot surface.
For the best calibrated accuracy, the effect of the higher temperature on the velocity of sound must be taken into account. Although change in sound velocity with temperature is much less in metals than in plastics, significant errors in measured thickness can result if sound velocity is not corrected.
We recommends the Model 35DL, which can be used with delay line transducers or immersion transducers. On hot surfaces delay line transducers must be used with selected High Temperature delay lines.
|
The handheld MG2 ultrasonic thickness gage uses dual element transducers for corrosion applications. It offers many basic features such as Min/Max Mode that measures and recalls the minimum thickness at a fast 20 readings per second, Freeze Mode to instantly capture critical thickness, and Zero Compensation.Copyright 2011 OLYMPUS CORPORATION, All rights reserved. Terms Of Use | Privacy Statement