Inspection & Measurement Systems

Defektoskopy

Głowice normalne na z Fale poprzeczne

Normal Incidence Shear Wave Transducers

Single element normal incidence Shear Wave Transducers contact transducers introduce shear waves directly into the test piece without the use of refracted wave mode conversion.

We recommend the use of our SWC shear wave couplant for general purpose testing.

Advantages:

  • Generate shear waves which propagate perpendicular to the test surface
  • For ease of alignment, the direction of the polarization of shear wave is nominally in line with the right angle connector
  • The ratio of the longitudinal to shear wave components is generally below -30 dB

Applications:

  • Shear wave velocity measurements
  • Calculation of Young's Modulus of elasticity and shear modulus (see Technical Notes, page 46)
  • Characterization of material grain structure

Direct Contact Series

  • WC-5 wear plate increases durability and wear resistance
  • Available in both the Standard and Fingertip case styles
  • 303 stainless steel case

Transducer Configurator

Frequency (MHZ)
Nominal Element Size (in)
Transducer Type
Frequency
(MHz)
Nominal Element Size VIDEOSCAN
in.mmPart /
Item No.
1 1 25 V1548

U8403067

Contact Transducer, 0.1 MHz, 1.00 in. Shear Element Diameter, Standard Case Style, Right BNC Connector Includes Test Form Certificate
25 1 25
V150-RB

U8403055

Contact Transducer, 0.25 MHz, 1.00 in. Element Diameter, Standard Case Style, Right BNC Connector Includes Test Form Certificate
V150-RM

U8403056

Contact Transducer, 0.25 MHz, 1.0 in. Element Diameter, Fingertip Case Style, Right Microdot Connector Includes Test Form Certificate
5 1 25
V151-RB

U8403058

Contact Transducer, 0.50 MHz, 1.00 in. Shear Element Diameter, Standard Case Style, Right BNC Connector Includes Test Form Certificate
V151-RM

U8403059

Contact Transducer, 0.50 MHz, 1.00 in. Shear Element Diameter, Fingertip Case Style, Right Microdot Connector Includes Test Form Certificate
1 0.5 13
V153-RM

U8403065

Contact Transducer, 1.00 MHz, 0.50 in. Shear Element Diameter, Fingertip Case Style, Right Microdot Connector Includes Test Form Certificate
V153-RB

U8403064

Contact Transducer, 1.00 MHz, 0.50 in. Shear element size, Standard Case Style, Right BNC Connector Includes Test Form Certificate
1 1 25
V152-RB

U8403061

Contact Transducer, 1.00 MHz, 1.00 in. Shear Element Diameter, Standard Case Style, Right BNC Connector Includes Test Form Certificate
V152-RM

U8403062

Contact Transducer, 1.00 MHz, 1.00 in. Shear Element Diameter, Fingertip Case Style, Right Microdot Connector Includes Test Form Certificate
225 0.5 13
V154-RM

U8403069

Contact Transducer, 2.25 MHz, 0.50 in. Shear element size, Fingertip Case Style, Right Microdot Connector Includes Test Form Certificate
V154-RB

U8403068

Contact Transducer, 2.25 MHz, 0.50 in. Shear Element Diameter, Standard Case Style, Right BNC Connector Includes Test Form Certificate
5 0.125 3 V157-RM

U8403075

Contact Transducer, 5.00 MHz, 0.125 in. Shear Element Diameter, Fingertip Case Style, Right Microdot Connector Includes Test Form Certificate
5 0.25 6 V156-RM

U8403074

Contact Transducer, 5.00 MHz, 0.25 in. Shear element size, Fingertip Case Style, Right Microdot Connector Includes Test Form Certificate
5 0.5 13
V155-RM

U8403072

Contact Transducer, 5.00 MHz, 0.50 in. Shear Element Diameter, Fingertip Case Style, Right Microdot Connector Includes Test Form Certificate
V155-RB

U8403071

Contact Transducer, 5.00 MHz, 0.50 in. Shear Element Diameter, Standard Case Style, Right BNC Connector Includes Test Form Certificate

Delay Line Series

  • Integral delay line permits measurements at higher frequencies
  • Fused silica delay line minimizes attenuation and provides physical protection to the crystal element

Frequency

Nominal
Element Size

Delay

Transducer
Part Numbers

MHz

inches

mm

µsec

5.0

0.25

6

7

V220-BA-RM

10

0.25

6

7

V221-BA-RM

0.25

6

7

V222-BA-RM

20 0.25 6 7 V222-BB-RM
0.25 6 4 v222-BC-RM

Shear Wave Couplant

SWC

4 oz.
(0.12 liter)

Normal Incidence Shear Wave, non-toxic, water soluble organic substance of very high viscosity
Loading...

English | 日本語 | français | 简体中文 | Deutsch | italiano | čeština | magyar | Tiểng Việt | Español | русский | polski | português | 한국어