| SCOPE VARIATION | ||||||
| Model No. | Scope
Diameter | Scope Length | Tube Flexibility | Articulation Angle
UP/DOWN/ RIGHT/LEFT | Approx. System Weight
(with battery) | |
| IPLEX LX | IPLEX LT | |||||
| IV8420L1 | IV8420L2 |
Ø4.0 mm
(0.157 in) |
2.0 m
(6.6 ft) | Uniformed stiffness | 130° |
2.7 kg
(6.0 lb) |
| IV8435L1 | IV8435L2 |
3.5 m
(11.5 ft) |
2.8 kg
(6.2 lb) | |||
| IV8620L1 | IV8620L2 | Ø6.0 mm (0.236 in) |
2.0 m
(6.6 ft) | Tough Tapered Flex™ tube with flexibility gradually increasing toward the distal end. | 150° | |
| IV8635L1 | IV8635L2 | 3.5 m (11.5 ft) | 130° |
2.9 kg
(6.4 lb) | ||
| IV8675L1 | IV8675L2 | 7.5 m (24.6 ft) | 90° |
3.2 kg
(7.1 lb) | ||
|
IV8835L1
|
IV8835L2
| Ø8.5 mm (0.335 in) | 3.5 m (11.5 ft) | 140° |
3.0 kg
(6.6 lb) | |
| IV88100L1 | IV88100L2 | 10.0 m (32.8 ft) | 115° |
3.9 kg
(9.0 lb) | ||
|
IV88200L11
|
IV88200L2 1
|
20.0 m
(65.6 ft) | Uniformed stiffness | 70° |
5.2 kg
(11.5 lb) | |
*1. Built-to-order
| INSERTION TUBE | |
| Exterior |
High durability tungsten braid
|
| Articulation Mechanics | TrueFeel™ scope tip articulation with electronic power-assisted, manual articulation. |
| Temperature Sensor | IPLEX LX only: 2-stage indicator for high temperature warning. |
| HANDHELD CONTROL UNIT | |
| Dimensions (W x D x H) | 311 mm x 93 mm x 192 mm (12.2 in. x 3.7 in. x 7.6 in.) |
| Weight | Approx. 750 g (1.7 lb) |
| Quick access buttons | The following features have dedicated quick access buttons, levers or joysticks on the hand control unit: Live mode, WiDER™ Gain Control (IPLEX LX only), Brightness, Zoom, Freeze Image, Record Still/Video, Articulation Control, Articulation Lock, Menu Access, Saved Recording Index Access, Quick Last Image Recall. |
| MAIN UNIT | |
| Dimensions (W x D x H) |
Main Unit: 227 mm x 189 mm x 64 mm (8.9 in. x 7.4 in. x 2.5 in.)
Maximum Dimension: 239 mm x 215 mm x 99 mm (9.4 in. x 8.5 in. x 3.9 in.) |
| LCD monitor | 6.5 in. daylight-view LCD, anti-reflective type |
| Power Supply |
Battery: 10.8 V nominal.
IV84 and IV86 Series: over 120-minute operating time. IV88 Series: over 100-minute operating time. AC power: 100 V to 240 V, 50/60 Hz (with supplied AC adapter) |
| Output Connector | RCA composite video output |
| USB Connector | Type A connector, Version 2.0 standards |
| SOFTWARE CONTROLS | |
| Image Controls | 5 X digital zoom, 8 step brightness control |
| Adjustable Gain Control | IPLEX LX only: 3 step adjustable gain control with exclusive WiDER™ brightness level balancing technology. |
| Display Text Options | 30-character tite display |
| RECORDING MANAGEMENT FUNCTIONS | |
| Recording Media | USB flash drive (1 GB standard, compatible with recommended USB flash device). |
| Overlay | Selectable 30 character title with date, time and system setting. |
| Thumbnail image display | Recorded images can be displayed as thumbnails. |
| Still image Recording | Resolution - NTSC: H 640 x V 480 (Pixel), PAL: H 768 x V 576 (Pixel) |
| Recording Format - Compressed JPEG format | |
| Size of a single image - Approx. 300 KB (Approx. 3,400 images per 1 GB memory) | |
| Video Recording | Resolution - H 640 ×V 480 (Pixel) |
| Recording Format - AVI MPEG-4 format. Can be played on the Windows Media Player. | |
| Size of a single image - Approx. 500 KB per second (Approx. 30 min. per 1 GB memory) | |
| STEREO MEASUREMENT FUNCTIONS - Optional function for IPLEX LX | ||
| Distance | Distance between two points. | Note: Stereo Measurement functions are available by upgrading the IPLEX LX. |
| Point-to-Line | Perpendicular distance between a point and a user-defined line. | |
| Depth | Orthogonal depth/height distance between a point and a user-defined plane. | |
| OPERATING ENVIRONMENT | ||
| Operating Temperature | Insertion Tube |
In air:
-25 ºC to 100 ºC (-13 ºF to 212 ºF) IPLEX LX -25 ºC to 80 ºC (-13 ºF to 176 ºF) IPLEX LT and IPLEX LX IV88100L1 In water: 10 ºC to 30 ºC (50 ºF to 86 ºF) |
| Other parts than above | In air: -10 °C to 40 ºC (14 ºF to 104 ºF) | |
| Operating Atmospheric Pressure | Insertion Tube |
In air: 1013 hPa
In water: IV84 series - 1013 to 1368 hPa IV86 series - 1013 to 1772 hPa IV88 series - 1013 to 2026 hPa |
| Other parts than above | In air: 1013 hPa | |
| Relative Humidity | All parts | 15 % to 90 % |
| Liquid Resistance | All parts | Operable when exposed to machine oil, light oil or 5 % saline solution. |
| Waterproofing | Insertion Tube |
Operable under water with viewing tip adapter attached.
Not operable underwater with stereo measurement tip adapters. |
| Other parts than above |
Operable in blowing rain conditions (Battery compartment must be closed).
Not operable underwater. | |
| MIL-STD COMPLIANCE | |
| The operating environment performance is confirmed by the following MIL-STD-810G and MIL-STD-461F under battery operation. | |
| Type | Method |
| Vibration1 | MIL-STD-810G, Method 514.5, Procedure I (General vibration test). |
| Shock | MIL-STD-810G, Method 516.5, Procedure IV (Transit drop test). |
| Water Resistance1 | MIL-STD-810G, Method 506, Procedure I (Rain and Blowing rain test). |
| Humidity1 | MIL-STD-810G, Method 507.4 |
| Salt Fog1 | MIL-STD-810G, Method 509 |
| Sand and Dust1 | MIL-STD-810G, Method 510.4, Procedure I (Blowing dust test). |
| Icing/Freezing Rain1 | MIL-STD-810G, Method 521.2 |
| Electromagnetic Interference (EMI)2 | MIL-STD-461F, RS-103, (Radiated susceptibility test for non-metallic above deck shipboard conditions). |
| Explosive Atmosphere1 | MIL-STD-810G, Method 511.4, Procedure I (Operation in an explosive atmosphere test). |
*1. Excluding IV8835L1/L2, IV88100L1/L2, IV88200L1/L2.
*2. Excluding IV8675L1/L2, IV8835L1/L2, IV88100L1/L2 and IV88200L1/L2.
| OPTICAL TIP adapter VARIATION | ||||||
| Optical Adapter | Optical system | Distal end | ||||
| Field of view | Direction
of view | Depth of field3 | Outer diameter4 | Distal end5 | ||
| 6.0 mm Viewing Tip adapters | AT40D-IV86 | 40º | Forward | 200 to ∞ mm | ø6.0 mm | 19.8 mm |
| AT80D/NF-IV86 | 80º | 8 to ∞ mm | ||||
| AT80D/FF-IV86 | 80º | 35 to ∞ mm | ||||
| AT120D/NF-IV86 | 120º | 4 to 190 mm | ||||
| AT120D/FF-IV86 | 120º | 25 to ∞ mm | ||||
| AT80S-IV86 | 80º | Side | 18 to ∞ mm | 25.2 mm | ||
| AT120S/NF-IV86 | 120º | 1 to 25 mm | ||||
| AT120S/FF-IV86 | 120º | 5 to ∞ mm | ||||
| 4.0 mm Viewing Tip Adapters | AT120D/NF-IV84 | 120º | Forward | 4 to 190 mm | ø4.0 mm | 19.7 mm |
| AT120D/FF-IV84 | 120º | 25 to ∞ mm | 19.6 mm | |||
| AT120S/NF-IV84 | 120º | Side | 1 to 20 mm | 22.2 mm | ||
| AT120S/FF-IV84 | 120º | 6 to ∞ mm | ||||
| 8.5 mm Viewing Tip Adapters | AT80D/FF-IV88 | 80º | Forward | 35 to ∞ mm | ø8.5 mm | 22.9 mm |
| AT120D/NF-IV88 | 120º | 4 to 190 mm | ||||
| AT120D/FF-IV88 | 120º | 25 to ∞ mm | 29.5 mm | |||
| AT120S/NF-IV88 | 120º | Side | 1 to 25 mm | |||
| AT120S/FF-IV88 | 120º | 5 to ∞ mm | ||||
|
Stereo Tip Adapters
(4.0 mm, 6.0 mm, and 8.5 mm) | AT50D/50D-IV84 | 50º/50º | Forward/Forward | 5 to ∞ mm | ø4.0 mm | 25.0 mm |
| AT50S/50S-IV84 | 50º/50º | Side/Side | 4 to ∞ mm | 28.8 mm | ||
| AT60D/60D-IV86 | 60º/60º | Forward/Forward | 5 to ∞ mm | ø6.0 mm | 25.9 mm | |
| AT60S/60S-IV86 | 60º/60º | Side/Side | 4 to ∞ mm | 32.2 mm | ||
| AT60D/60D-IV88 | 60º/60º | Forward/Forward | 5 to ∞ mm | ø8.5 mm | 28.9 mm | |
| AT60S/60S-IV88 | 60º/60º | Side/Side | 4 to ∞ mm | 36.5 mm | ||
| Tip adapter General Specifications | |
| Locking Mechanism | Double Threaded Attachment, with O-ring seal. |
| Illumination | Multiple ultra-high intensity LEDs. IPLEX LX only: 2-stage setting for extra-bright illumination. |
| Tip adapter Identification6 | IPLEX LX only: SmartTip™ Automatic Recognition Technology |
*3. Indicates the viewing distance with optimal focus.
*4. The adapter can be inserted into a ø4.0 mm, ø6.0 mm or ø8.5 mm hole when it is mounted on the scope.
*5. Indicates the length of the rigid portion at the scope's distal end when mounted.
*6. Not available on the 8.5 mm tip adapters.
Copyright 2011 OLYMPUS CORPORATION, All rights reserved. Terms Of Use | Privacy Statement