Surface probes have smaller diameter housing and coils built for higher frequencies. Applications are usually limited to surface flaws because of the higher frequency and smaller coil size. Included in this type of probe are the right angle surface probes and flexible surface probes, which are designed to reach areas inaccessible to the standard straight surface probes.
| Microdot Connector | Triax Fischer/LEMO Connector |
PowerLink Connector
(7-pin LEMO) | |||||
| Frequency Range | Part Number | Item Number | Part Number | Item Number | Part Number | Item Number | Overall Length
mm (in.) |
| Straight Probes | |||||||
| 50 kHz to 500 kHz | MP-40 | U8620067 | MTF-40 | U8623038 | 9403359 | U8629526 | 101 (4) |
| 200 kHz to 1 MHz | MP-40-200K-1M | U8620069 | MTF-40-200K-1M | U8610675 | 9403403 | U8629527 | 101 (4) |
| 1 MHz to 3 MHz | MP-40-1-3M | U8620068 | n.a. | n.a. | n.a. | n.a. | 101 (4) |
| 1 MHz to 6 MHz | n.a. | n.a. | MTF-40-1-6M | U8623039 | 9403404 | U8629528 | 101 (4) |
| Right Angle Shaft, 0.03 in. (0.76 mm) Drop | |||||||
| 50 kHz to 500 kHz | MP9003-60 | U8620348 | MTF9003-60 | U8623070 | 9403405 | U8629529 | 152 (6) |
| 200 kHz to 1 MHz | MP9003-60-200K-1M | U8620397 | MTF9003-60-200K-1M | U8623342 | 9403406 | U8620399 | 152 (6) |
| 1 MHz to 3 MHz | MP9003-60-1-3M | U8620398 | n.a. | n.a. | n.a. | n.a. | 152 (6) |
| 1 MHz to 6 MHz | n.a. | n.a. | MTF9003-60-1-6M | U8610773 | 9403407 | U8620400 | 152 (6) |
| Right Angle Shaft, 0.20 in. (5.08 mm) Drop | |||||||
| 50 kHz to 500 kHz | MP902-60 | U8620167 | MTF902-60 | U8623083 | 9403360 | U8629530 | 152 (6) |
| 200 kHz to 1 MHz | MP902-60-200K-1M | U8620401 | MTF902-60-200K-1M | U8623085 | 9403408 | U8629531 | 152 (6) |
| 1 MHz to 3 MHz | MP902-60-1-3M | U8620168 | n.a. | n.a. | n.a. | n.a. | 152 (6) |
| 1 MHz to 6 MHz | n.a. | n.a. | MTF902-60-1-6M | U8623084 | 9403409 | U8629532 | 152 (6) |
| Right Angle Shaft, 0.50 in. (12.7 mm) Drop | |||||||
| 50 kHz to 500 kHz | MP905-60 | U8620200 | MTF905-60 | U8623108 | 9403410 | U8629533 | 152 (6) |
| 200 kHz to 1 MHz | MP905-60-200K-1M | U8610518 | MTF905-60-200K-1M | U8623312 | 9403411 | U8629534 | 152 (6) |
| 1 MHz to 3 MHz | MP905-60-1-3M | U8620201 | n.a. | n.a. | n.a. | 152 (6) | |
| 1 MHz to 6 MHz | n.a. | n.a. | MTF905-60-1-6M | U8623111 | 9403412 | U8629535 | 152 (6) |
Metal shaft surface probes are general purpose probes used for surface or near surface crack detection. They are also used for conductivity and coating thickness measurements. Configured with absolute (Microdot connector) or bridge coils (Fischer/LEMO triax connector). Reference coils are internal to the probe in the bridge configuration probes (Fischer/LEMO triax connector), insuring the best match to the test coil without an external adapter. Probes are detachable with either Microdot or Fischer/LEMO triax connectors.