CDS-Vorlaufkeile sind vorgesehen für die Erzeugung einer Transversalwelle von 30 Grad und einer Longitudinalwelle von 70 Grad in Stahl zur Fehlergrößenbestimmung mit der 30-70-70-Methode. Sie messen insbesondere bis an die Innenwand reichende Risse.
The 30-70-70 crack detection technique uses a single element transducer with a CDS wedge for detection and sizing of ID connected cracks. This technique uses a combination of three waves for sizing flaws of different depths.
Based on the presence or absence of these three waves, both detection and sizing of ID connected cracks is possible.

CDS Wedges are used in the "30-70-70" technique for crack detection and sizing. They are compatible with our replaceable miniature screw-in angle beam transducers, making them an economical alternative to other commercially available products.
Fits Nominal Element Size | Wedge Part Number | |
inches | mm | |
0.25 | 6 | CDS-4T |
0.375 | 10 | CDS-7T |
Copyright 2011 OLYMPUS CORPORATION, Alle Rechte vorbehalten. Nutzungsbedingungen | Datenschutzerklärung