1 00:00:13,481 --> 00:00:15,450 Welcome to this quick start video 2 00:00:15,450 --> 00:00:19,386 on the new Olympus Vanta handheld XRF analyzer. 3 00:00:19,386 --> 00:00:22,156 In this video, you will see how quick and easy it is 4 00:00:22,156 --> 00:00:25,626 to use your Vanta analyzer right out of the case. 5 00:00:25,626 --> 00:00:28,763 When you first open the case, you’ll find: 6 00:00:28,763 --> 00:00:30,998 Your Vanta analyzer, 7 00:00:30,998 --> 00:00:33,366 The AC power adaptor, 8 00:00:33,366 --> 00:00:35,470 A USB cable, 9 00:00:35,470 --> 00:00:38,640 Two Lithium-ion batteries, 10 00:00:38,640 --> 00:00:41,608 10 extra Kapton or Prolene windows 11 00:00:41,608 --> 00:00:43,176 depending on the model, 12 00:00:43,176 --> 00:00:45,746 A USB drive with product documentation 13 00:00:45,746 --> 00:00:48,148 and Vanta desktop software, 14 00:00:48,148 --> 00:00:51,351 A micro SD card that is already installed 15 00:00:51,351 --> 00:00:54,355 in your analyzer microSD port, 16 00:00:54,355 --> 00:00:58,460 and the Vanta analyzer docking station 17 00:00:58,460 --> 00:01:00,328 On the top of the analyzer, 18 00:01:00,328 --> 00:01:04,265 the data port cover protects the Vanta data ports and connections. 19 00:01:04,265 --> 00:01:06,300 To open the cover, lift the ring 20 00:01:06,300 --> 00:01:09,603 and turn it counterclockwise until the cover releases. 21 00:01:09,603 --> 00:01:13,708 From here you can access the analyzer MicroSD port, 22 00:01:13,708 --> 00:01:15,910 The AC adaptor socket, 23 00:01:15,910 --> 00:01:18,145 Two standard USB connectors, 24 00:01:18,145 --> 00:01:20,781 And one Mini USB connector. 25 00:01:20,781 --> 00:01:25,453 To use the analyzer, insert one of the fully charged batteries. 26 00:01:25,453 --> 00:01:28,990 The battery is keyed to fit in only one direction. 27 00:01:28,990 --> 00:01:31,491 If the battery won’t easily go in, 28 00:01:31,491 --> 00:01:34,695 take it out, rotate it, and try it again. 29 00:01:34,695 --> 00:01:37,065 When the battery is inserted correctly, 30 00:01:37,065 --> 00:01:39,700 the hinged latches on both sides of the handle 31 00:01:39,700 --> 00:01:43,471 lock into place with an audible click. 32 00:01:43,471 --> 00:01:46,173 Every Vanta comes with an AC adaptor. 33 00:01:46,173 --> 00:01:48,308 This can be used to power the analyzer 34 00:01:48,308 --> 00:01:51,545 with or without a battery installed in the handle. 35 00:01:51,545 --> 00:01:54,648 The AC adaptor can also power the docking station 36 00:01:54,648 --> 00:01:57,318 to recharge the battery installed in the Vanta 37 00:01:57,318 --> 00:02:01,121 and the spare battery in the docking station auxiliary socket. 38 00:02:01,121 --> 00:02:03,525 To power the Vanta docking station, 39 00:02:03,525 --> 00:02:06,895 plug the AC adaptor into the back of the docking station. 40 00:02:06,895 --> 00:02:11,631 Place the spare battery in the auxiliary socket. 41 00:02:11,631 --> 00:02:16,070 Press the power button on the back of the analyzer to turn it on. 42 00:02:16,070 --> 00:02:18,940 The Vanta welcome screen appears. 43 00:02:18,940 --> 00:02:22,276 Make sure to read the radiation safety warning. 44 00:02:22,276 --> 00:02:26,180 After you’ve read the radiation safety warning, log in. 45 00:02:26,180 --> 00:02:29,250 Tap the leftmost box to display the keypad, 46 00:02:29,250 --> 00:02:32,053 and enter the password. 47 00:02:32,053 --> 00:02:34,955 Below the touch screen are three buttons. 48 00:02:34,955 --> 00:02:39,293 Two of these buttons are used to control the user interface. 49 00:02:39,293 --> 00:02:41,428 These buttons are useful when conditions 50 00:02:41,428 --> 00:02:43,430 prevent you from touching the screen, 51 00:02:43,430 --> 00:02:45,433 like when you’re wearing gloves. 52 00:02:45,433 --> 00:02:48,401 The leftmost button is the back button. 53 00:02:48,401 --> 00:02:52,473 Press this to return to the previous data field in the UI. 54 00:02:52,473 --> 00:02:55,108 The center button is the joystick. 55 00:02:55,108 --> 00:02:57,278 The joystick moves in four directions 56 00:02:57,278 --> 00:03:02,416 up, down, left, and right. 57 00:03:02,416 --> 00:03:05,886 When pressed, the joystick functions as an enter button. 58 00:03:05,886 --> 00:03:09,556 The power button is on the far right. 59 00:03:09,556 --> 00:03:13,861 Let’s discuss proper use of your Vanta XRF analyzer. 60 00:03:13,861 --> 00:03:17,998 Before using your analyzer please review the user manual. 61 00:03:17,998 --> 00:03:21,468 Our instruments are safe and dependable when used correctly, 62 00:03:21,468 --> 00:03:24,538 so it’s important to thoroughly review the user manual 63 00:03:24,538 --> 00:03:27,408 to ensure best practices so that you 64 00:03:27,408 --> 00:03:30,545 and everyone around you will be safe. 65 00:03:30,545 --> 00:03:35,516 When the red light is flashing, X-rays are being emitted. 66 00:03:35,516 --> 00:03:39,120 Never point the analyzer at yourself. 67 00:03:39,120 --> 00:03:43,123 Never point the analyzer at anyone else. 68 00:03:43,123 --> 00:03:48,328 Never place your hand over or near the analyzer window. 69 00:03:48,328 --> 00:03:50,096 When you’re ready to perform a test, 70 00:03:50,096 --> 00:03:53,935 place your sample on a stable surface. 71 00:03:53,935 --> 00:03:56,570 To start a test, tap the start button 72 00:03:56,570 --> 00:03:59,606 on the screen or pull the trigger. 73 00:03:59,606 --> 00:04:02,076 To stop a test, tap the stop button 74 00:04:02,076 --> 00:04:04,378 or pull the trigger again. 75 00:04:04,378 --> 00:04:07,148 Some users utilize the “dead man trigger” 76 00:04:07,148 --> 00:04:09,050 where the trigger must be pulled 77 00:04:09,050 --> 00:04:11,451 for the entire duration of the test. 78 00:04:11,451 --> 00:04:14,355 Releasing the trigger stops the test. 79 00:04:14,355 --> 00:04:16,590 To activate the dead man trigger, 80 00:04:16,590 --> 00:04:23,831 pull down the menu bar and open the safety screen. 81 00:04:23,831 --> 00:04:27,468 All Vanta analyzers feature hot-swap batteries 82 00:04:27,468 --> 00:04:31,905 so you can change batteries without powering down the analyzer. 83 00:04:31,905 --> 00:04:33,908 To swap out the battery, 84 00:04:33,908 --> 00:04:37,211 remove the spent battery and insert a fresh one. 85 00:04:37,211 --> 00:04:40,815 A countdown screen shows you the power left in the analyzer 86 00:04:40,815 --> 00:04:44,518 so you know how much time you have to complete the swap. 87 00:04:44,518 --> 00:04:47,121 When you are done using your analyzer, 88 00:04:47,121 --> 00:04:49,856 press and hold the power button for one second. 89 00:04:49,856 --> 00:04:52,226 In the dialog box that appears 90 00:04:52,226 --> 00:04:56,530 tap OK to power off the analyzer. 91 00:04:56,530 --> 00:04:58,598 Place your Vanta in the docking station 92 00:04:58,598 --> 00:05:01,668 when not in use for safe storage. 93 00:05:01,668 --> 00:05:04,438 Vanta analyzers feature simple measurement 94 00:05:04,438 --> 00:05:08,208 window replacement without the need for any tools. 95 00:05:08,208 --> 00:05:11,611 To change the Kapton or Prolene measurement window, 96 00:05:11,611 --> 00:05:13,380 turn off the Vanta 97 00:05:13,380 --> 00:05:17,318 and then firmly push the release button on the bottom of the snout. 98 00:05:17,318 --> 00:05:19,753 Pull the faceplate down slightly from the bottom 99 00:05:19,753 --> 00:05:23,023 to release the top of the faceplate from the snout assembly. 100 00:05:23,156 --> 00:05:27,628 The faceplate swings down to expose the measurement window. 101 00:05:27,761 --> 00:05:35,836 Pull the old window off and replace it with a new one. 102 00:05:35,836 --> 00:05:38,706 Rotate the faceplate upward and push in 103 00:05:38,706 --> 00:05:41,108 until it clicks into place. 104 00:05:41,108 --> 00:05:43,110 To avoid expensive repairs, 105 00:05:43,110 --> 00:05:46,213 be careful not to touch the inside of the analyzer 106 00:05:46,213 --> 00:05:50,818 or allow dirt or other objects into the analyzer. 107 00:05:50,818 --> 00:05:53,486 Thank you for watching this quick start video 108 00:05:53,486 --> 00:05:56,456 for the Olympus Vanta XRF Analyzer. 109 00:05:56,456 --> 00:06:00,026 For more information, please contact your local representative 110 00:06:00,026 --> 00:06:07,033 or visit us online at www.olympus-ims.com.