The OmniScan MX2 phased array flaw detector with touch screen interface offers increased testing efficiencies and powerful software features, ensuring superior manual and advanced AUT application performance with fast setups, test cycles, and reporting. It is compatible with all existing phased array modules.
This second generation OmniScan MX2 increases testing efficiencies, ensuring superior manual and advanced AUT application performance with faster setups, test cycles, and reporting, in addition to universal compatibility with all phased array and ultrasound modules: past, present and future. Designed for NDT leaders, this high-end, scalable platform delivers true next-generation NDT performance.
The OmniScan MX2 offers a high acquisition rate and new powerful software features for efficient manual and automated inspection performance- all in a portable, modular instrument.
Faster Is Better!Powerstart your day the right way with the OmniScan MX2. The OmniScan MX2 simplifies and speeds up the setup process with its new Weld Overlay software feature, so you can start testing immediately. Featuring the industry-standard phased array user interface with faster-than-ever performance, a bigger and brighter 10.4 in. screen, new and unique intuitive touch-screen capabilities, and faster data transfer, enabling you to get to your next inspection quicker. More Rugged than EverThe OmniScan MX2 is now designed for IP66, and built to withstand the drops, spills, and abuse that typically occur in the most demanding inspection environments. |
The OmniScan MX2 is an important part of your inspection solution, and can be combined with other critical components to form a complete inspection system. Olympus offers a complete product range that includes phased array probes, scanners, analysis software, and accessories, all of which are integrated and packaged into rapidly deployable, application-specific solutions for quick returns on your investment. In addition, Olympus offers a high-quality calibration and repair service worldwide, which is backed by a team of phased array application experts to ensure that you get the support you need.

The revolutionary touch-screen interface offers simple and quick navigation, enhanced text input functions, and easier, faster cursor control and gate setup.

The unique full-screen mode offers operators increased viewing comfort, in addition to better readability at a distance. This feature can be used in both acquisition and analysis mode.
The Weld Overlay Wizard facilitates the creation of industry-standard weld overlays for analysis assistance and volumetric flaw placement.


| OmniScan MX | ![]() |
| OmniScan MX2 | 50% larger screen
|
| OmniScan MX | ![]() |
| OmniScan MX2 | 100% brighter screen
|
Backward Compatible. Forward Compatible.
An Evolving Platform for your Growing Needs.
Designed to secure both your current and future phased array investments, the OmniScan MX2 can house any Olympus phased array module, including the reliable, field-proven models currently available, and the next-generation modules of the future. Its open architecture also supports future software updates and phased array module upgrades with configurations from 16:64M to 32:128 to ensure that your instrument evolves with your testing needs, and that you get the most from your investment.
| Module Compatibility | OmniScan MX2 | OmniScan MX |
| OMNI-M-PA1664M | ✔ | ✔ |
| OMNI-M-PA1664 | ✔ | |
| OMNI-M-PA16128 | ✔ | ✔ |
| OMNI-M-PA32128 | ✔ | ✔ |
| OMNI-M-PA32128PR | ✔ | ✔ |
| OMNI-M-PA3232 (200 V) | ✔ | ✔ |
| OMNI-M-UT | ✔ | ✔ |
| OMNI-M-ECT/ECA | ✔ | ✔ |
| Software Compatibility | ||
| MXU-3.X1 | ✔ | |
| MXU-2.X setup and data files | ✔ | ✔ |
| TomoView 2.9R12 (or higher)1 | ✔ | ✔ |
| TomoView Remote Control | ✔ | ✔ |
| 1. Data file compatibility | ||
The bright 10.4 in. screen with its new, innovative, and revolutionary touch-screen interface improves browsing speed with its user-friendly gate, cursor, and display controls. In addition, the new on-screen text and value input makes devices like mice and keyboards unnecessary.
Menu Selection and Parameter Settings

Tap once on the screen to quickly navigate through menus, submenus, and parameters.
Zooming and Panning

The touch screen's zooming functions can be used to zoom in on a specific area.

In Zoom mode, swipe to pan the window contents.
Gate Selection and Movement

In Gate mode, tap and hold a gate to move it to a new position.
Cursor Selection and Movement

In Cursor mode, tap once on a cursor to select it. Double-tap on a position to move the cursor to the desired location.
Text and Value Input

Double-tap on a parameter to bring up the keyboards or keypad on which values can be entered. Alphabetic and numeric keyboards are available.

Scan plan adjustment using the Focal Law Wizard.

UT parameter adjustment using the touch-screen software keypad.
Group Wizard for All Essential Parameters
| Setup Speed | |
| OmniScan MX | ![]() |
| OmniScan MX2 | 50% faster
|
| S-Scan and A-Scan Display Refresh Rate | |
| OmniScan MX | ![]() |
| OmniScan MX2 | 300% better
|

Sensitivity calibration for a defined section in a sectorial scan.

Sensitivity calibration for all beams in a sectorial scan.
Code-Compliant Calibration
The Calibration Wizards ensure that every focal law in every group is the direct equivalent of a single-channel conventional flaw detector.
Calibration Wizards

Top: Data acquisition displaying TOFD.
Right: Data acquisition displaying two phased array channels and TOFD.
| Pulse Repetition Frequency (PRF) | |
| OmniScan MX | ![]() |
| OmniScan MX2 | 40% better
|
| Saving Inspection Data File to USB (speed) | |
| OmniScan MX | ![]() |
| OmniScan MX2 | Up to 400% times better
|
| Maximum File Size (Mb) | |
| OmniScan MX | 160 Mb
|
| OmniScan MX2 | 300 Mb
|

Weld inspection display showing the position of indications in the RayTracing display.
An SD Card is used to store data for easy transfer to a computer. The SD card can also be inserted and removed without having to reboot the unit. In addition, data can be transferred to external media using the USB 2.0 port. The OmniScan MX2 provides data transfer speeds up to 400% faster than the OmniScan MX (depending on the device used).

The OmniScan MX2 is designed to inspect, analyze, and generate reports directly on the instrument, or off-line on a computer.
| General | |
| Overall dimensions (W x H x D) |
325 mm x 235 mm x 130 mm
(12.8 in. x 9.3 in. x 5.1 in.) |
| Weight | 5 kg (11 lb), including module and one battery |
| Data Storage | |
| Storage devices | SDHC card, most standard USB storage devices, or fast Ethernet |
| Data file size | 300 MB |
| I/O Ports | |
| USB ports | 3 |
| Speaker out | Yes |
| Video output | Video out (SVGA) |
| Ethernet | 10/100 Mbps |
| I/O Lines | |
| Encoder | 2-axis encoder line (quadrature, up, down, or clock/direction) |
| Digital input | 4 digital TTL inputs, 5 V |
| Digital output | 4 digital TTL outputs, 5 V, 15 mA |
| Acquisition on/off switch | Remote acquisition enabled TTL, 5 V |
| Power output line | 5 V, 500 mA power output line (short-circuit protected) |
| Alarms | 3 TTL, 5 V, 15 mA |
| Analog output | 2 analog outputs (12 bits) ±5 V in 10 kΩ |
| Pace input | 5 V TTL pace input |
| Display | |
| Display size | 26.4 cm (10.4 in.) (diagonal) |
| Resolution | 800 pixels x 600 pixels |
| Brightness | 700 cd/m2 |
| Number of colors | 16 million |
| Type | TFT LCD |
| Power Supply | |
| Battery type | Smart Li-ion battery |
| Number of batteries | 1 or 2 (battery chamber accommodates two hot-swappable batteries) |
| Battery life | Minimum 6 hours with two batteries |
| Environmental Specifications | |
| Operating temperature range |
0 °C to 45 °C; 0 °C to 35 ºC with 32:128 PA
(32 ºF to 113 ºF; 32 ºF to 95 ºF with 32:128 PA) |
| Storage temperature range |
-20 °C to 60 °C (-4 ºF to 140 ºF) with batteries
-20 °C to 70 °C (-4 ºF to 158 ºF) without batteries |
| Relative humidity |
0% to 85% noncondensing
No air intake; designed for IP66 |
| Shockproof rating | Drop-tested according to MIL-STD-810G 516.6 |
| General | |
| Overall dimensions (W x H x D) |
244 mm x 182 mm x 57 mm
(9.6 in. x 7.1 in. x 2.1 in.) |
| Weight | 1.2 kg (2.6 lb) |
| Connectors | 1 OmniScan connector for phased array probes |
| Number of focal laws | 256 |
| Probe recognition | Automatic probe recognition |
| Pulser/Receiver | |
| Aperture | 32 elements |
| Number of elements | 128 elements |
| Pulser | |
| Voltage | 45 V or 90 V per element |
| Pulse width | Adjustable from 30 ns to 500 ns, resolution of 2.5 ns |
| Pulse shape | Negative square wave |
| Output impedance | Less than 30 Ω |
| Receiver | |
| Gain | 0 dB to 74 dB, maximum input signal 1.25 Vp-p |
| Input impedance | 50 Ω |
| System bandwidth | 0.53 MHz to 21 MHz (-3 dB) |
| Beamforming | |
| Scan type | Sectorial and linear |
| Group quantity | Up to 8 |
| Active elements | 32 |
| Elements | 128 |
| Data Acquisition | |
| Digitizing frequency | 100 MHz (10 bits) |
| Maximum pulsing rate | Up to 10 kHz (C-scan) |
| Data Processing | |
| Number of data points | Up to 8,000 |
| Real-time averaging | 2, 4, 8, 16 |
| Rectifier | RF, full wave, halfwave +, halfwave - |
| Filtering | Low-pass (adjusted to probe frequency), digital filtering (bandwidth, frequency range) |
| Video filtering | Smoothing (adjusted to probe frequency range) |
| Data Visualization | |
| A-scan refresh rate | Real time: 60 Hz |
| Data Synchronization | |
| On internal clock | 1 Hz to 10 kHz |
| On encoder | On 1 or 2 axes |
| Programmable Time-Corrected Gain (TCG) | |
| Number of points | 16 (1 TCG curve per channel for focal laws) |
| Alarms | |
| Number of alarms | 3 |
| Conditions | Any logical combination of gates |
| Analog outputs | 2 |
Request a quote for a custom phased array probe and/or wedge.
Copyright 2011 OLYMPUS CORPORATION, All rights reserved. Terms Of Use | Privacy Statement